• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See "Parts listing - BladeCenter HX5" on page 57 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
Description
Error code
3048006
Booted secondary (backup)
UEFI image because of
automatic boot failure
recovery
305000A
Real time clock (RTC) date/
time is incorrect
3058001
System configuration is not
valid
3058004
Three boot failures
Action
1. Run the Setup utility (see "Using the Setup utility" on page 20).
Select Load Default Settings and save the settings to recover the
server firmware.
2. Remove the blade server from the chassis.
3. Install the blade server into the chassis and turn on the blade server.
1. Run the Setup utility (see "Using the Setup utility" on page 20) to
adjust the date and time. Then, restart the blade server.
2. Reseat the battery.
3. Replace the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. (Trained service technician only) System board (see "Removing
the system-board assembly - BladeCenter HX5" on page 140
and "Installing the system-board assembly - BladeCenter HX5"
on page 142).
1. Run the Setup utility (see "Using the Setup utility" on page 20).
Select Load Default Settings and save the settings.
2. Reseat the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. Failing device. If the device is a field replaceable unit (FRU), it
must be replaced by a trained service technician.
3. Replace the following components one at a time in the order shown,
restarting the blade server each time:
a. Battery
b. Failing device. If the device is a field replaceable unit (FRU), it
must be replaced by a trained service technician.
c. (Trained service technician only) System board (see "Removing
the system-board assembly - BladeCenter HX5" on page 140
and "Installing the system-board assembly - BladeCenter HX5"
on page 142)
1. Undo any recent system changes, such as new settings or newly
installed devices.
2. Check the advanced management module event log for any power
related issues and resolve them. You can access the event log
through the advanced management module web interface. For more
information see the Advanced Management Module Installation and
User's Guide.
3. Remove all hardware that is not listed on the ServerProven website.
4. Run the Setup utility (see "Using the Setup utility" on page 20).
Select Load Default Settings and save the settings. Then, restart
the blade server.
.
159