Preparing Your Master Console Hardware Option Environment - IBM 2145UPS-1U Hardware Installation Manual

System storage san volume controller
Table of Contents

Advertisement

Preparing your master console hardware option environment

|
|
|
|
|
|
32
IBM System Storage SAN Volume Controller: Hardware Installation Guide
v SAN Volume Controller Console
v Adobe Reader
The following Web site provides the current list of supported software versions:
http://www.ibm.com/storage/support/2145
After the master console hardware is installed, the customer must configure the
software to meet their requirements.
If the master console hardware option is included with the SAN Volume
Controller, ensure that your physical site meets the installation requirements for
the master console hardware and the console monitor kit.
Server dimensions and weight
The following tables provide the physical characteristics and the environmental
requirements for the master console hardware option:
Height
Width
44 mm
480 mm
(1.7 in.)
(18.9 in.)
Server AC and input-voltage requirements
Power Supply
203 watt (110 or 220 V ac auto-sensing)
Server environment
Environment
Temperature
Server On
10° to 35°C
(50°F to 95°F)
Server Off
-40°C to 60°C
(-104°F to 140°F)
Server heat output
Approximate heat output in British thermal units (Btu) per hour:
v Minimum configuration: 87 watts (297 Btu)
Depth
Maximum Weight
426 mm
12.7 kg
(16.8 in.)
(28 lb)
Electrical Input
Sine-wave input (47–63 Hz) required
Input voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
Input kilovolt-amperes (kVA),
approximately:
Minimum: 0.0870 kVA
Maximum: 0.150 kVA
Altitude
Relative Humidity
0 to 914 m
8% to 80%
(2998.0 ft)
Maximum:
8% to 80%
2133 m
(6998.0 ft)