IBM 1000VA and 1500VA LCD Tower UPS
IBM System x at-a-glance guide
The IBM 1000VA and 1500VA LCD Tower Uninterruptible Power Supply (UPS) offerings provide power
protection with increased efficiency and simplified power management to safeguard high-availability IBM
System x server environments. With efficiency ratings of 95% or greater, these compact tower designs
can help reduce energy usage without compromising performance or reliability.
The IBM LCD Tower UPS is shown in Figure 1.
Figure 1. IBM LCD Tower Uninterruptible Power Supply
Did You Know?
The IBM 1000VA and 1500VA LCD Tower UPS offerings have a bright, easily customizable, and
graphical LCD display that lets you configure the device and displays important UPS status information in
one of nine languages.
These units can also enhance system availability with intelligent individual receptacle groups or load
segments that can be programmed and controlled, allowing mission-critical devices to be prioritized
during shutdown to preserve battery run time in the event of a prolonged power outage.
Additionally, these units come equipped with a communication bay that allows the installation of an
optional network management card (46M4110). The network management card provides convenient
over-the-network UPS remote monitoring and management through a standard web browser. This
solution features advanced capabilities, such as secure, remote flash upgradeable firmware for both the
UPS and network management card, which makes it an ideal solution for remote locations.
IBM 1000VA and 1500VA LCD Tower UPS
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM 1000VA

  • Page 1 Figure 1. IBM LCD Tower Uninterruptible Power Supply Did You Know? The IBM 1000VA and 1500VA LCD Tower UPS offerings have a bright, easily customizable, and graphical LCD display that lets you configure the device and displays important UPS status information in one of nine languages.
  • Page 2: Part Number Information

    Selecting the right IBM UPS can help protect against these potentially costly incidents. Part number information Table 1 shows the orderable part numbers and feature codes for the IBM 1000VA and 1500VA LCD Tower UPS offerings. Table 1. Ordering part numbers and feature codes...
  • Page 3 The 230 V models (1KX and 2KX) do not ship with line cords. Table 3 lists the compatible 230 V line cords from IBM, which are suitable for models 53961KX and 2KX; however, other customer ordered line cords can be used.
  • Page 4 Brazil 10A/250 V C13/ NBR 14136 (4.3 m) 81Y2387 Taiwan 10A/125 V C13/CNS 10917 (4.3 m) 81Y2388 Taiwan 10A/250 V C13/CNS 10917 (4.3 m) 81Y2389 Switzerland 10A/250 V C13/SEV 1011 (4.3 m) 81Y2390 IBM 1000VA and 1500VA LCD Tower UPS...
  • Page 5 Features The IBM 1000VA and 1500VA LCD Tower UPS offerings include the following features and capabilities: Compact tower chassis.  Energy efficient at over 95% at 100% load.  Offers eight output power receptacles split across two load segments. ...
  • Page 6: Specifications

    Specifications Table 4 lists the specifications for the IBM 1000VA and 1500VA LCD Tower UPS models. Table 4. Specifications Specification IBM 1000VA IBM 1000VA IBM 1000VA IBM 1500VA IBM 1500VA IBM 1500VA LCD Tower LCD Tower LCD Tower LCD Tower...
  • Page 7 2400 Joules rating Filtering ANSI/IEEE C62.41; 1991 CATEGORYB3 (SURGE) Table 5 lists the expected period that the IBM 1000VA LCD Tower UPS models will operate solely on batteries. Table 5. IBM 1000VA LCD Tower UPS runtime chart Load (%) Load (VA)
  • Page 8: Physical Specifications

    Table 6 lists the expected period that the IBM 1500VA LCD Tower UPS models will operate solely on batteries. Table 6. IBM 1500VA LCD Tower UPS runtime chart Load (%) Load (VA) Load (Watts) Run time (minutes) 375 VA 255 W...
  • Page 9 Model information: Displays the machine type, model, and serial number of the unit, and the firmware  level of the UPS, including the optional Network Management Card’s firmware level and IP address, if installed. Configuration: Allows you to change up to 17 user settings with minimal navigation.  IBM 1000VA and 1500VA LCD Tower UPS...
  • Page 10: Rear Panel

    To unlock the panel, press any button to perform its usual function. Rear panel Figure 3 shows the rear panel of the 230 V models of the IBM 1000VA LCD Tower UPS (53961KX) and IBM 1500VA LCD Tower UPS (53962KX).
  • Page 11 Figure 4 shows the rear panel of the 120 V models of the IBM 1000VA LCD Tower UPS (53961AX) and IBM 1500VA LCD Tower UPS (53962AX). The 100 V models (1JX and 2JX) look similar, although the IBM 1500VA LCD Tower UPS (100 V) 53962JX has an IEC 320 C20 input and eight NEMA 5-20R outputs.
  • Page 12: Network Management Card

    Network Management Card The IBM 1000VA and 1500VA LCD Tower UPS models also come equipped with a communication bay for the installation of an optional Network Management Card (46M4110). The Network Management Card provides convenient, over the network UPS remote monitoring and management through a standard web browser.
  • Page 13 Figure 6 shows the Network Management Card UPS properties window. Figure 6. IBM LCD UPS Network Management Card (NMC) UPS properties window IBM 1000VA and 1500VA LCD Tower UPS...
  • Page 14 UPS shutdown occurs. Figure 7 shows normal operating using the IBM UPS Manager. The input voltage is 122 V, which is within the acceptable range, and is shown in the left pane. The output voltage of the UPS is 121 V and is also within the acceptable range.
  • Page 15 Figure 8 shows that the utility power supply has failed and that the UPS is now operating on battery. The UPS Manager software indicates that there is 10 minutes of battery time available based on the current load. Figure 8. IBM UPS Manager warning status window IBM 1000VA and 1500VA LCD Tower UPS...
  • Page 16 Figure 9 shows the event notification window where you can configure how you (and other users) want to be notified when certain events occur. Figure 9. Event Notification window IBM 1000VA and 1500VA LCD Tower UPS...
  • Page 17: Ibm Environmental Monitoring Probe

    Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the  protected system. Its status can be monitored from the IBM Systems Director AEM or from the Network Management  Card web interface. It measures temperatures between 0 and 80°C (32 and 176°F) with an accuracy of ±1°C.
  • Page 18 AEM collects power information for each device attached to an IBM UPS, presenting a more complete view of energy usage within the data center. The IBM Systems Director Active Energy Manager (AEM) helps: Collect power information from each device attached to an IBM UPS, thus presenting a more ...
  • Page 19: Related Publications

    IBM US Product Announcement  http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS110-210 IBM System x tower UPS product page  http://www-03.ibm.com/systems/x/options/rackandpower/ups.html IBM 1000VA and 1500VA LCD Tower UPS Installation and Maintenance Guide  http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085920 Network Management Card User Guide  http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085199 IBM System x Configuration and Options Guide ...
  • Page 20 Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 21 Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml...

This manual is also suitable for:

1500va

Table of Contents