Grizzly G0796 Owner's Manual page 10

Vertical mill w/power feed & dro
Table of Contents

Advertisement

X-Axis Power Feed Identification
The mill is equipped with a power feed unit for
X-axis table movement. Refer to Figure 5 and the
descriptions below to understand the functions of
the various components of the power feed system.
AB
AF
AG
AH
AI
Figure 5. X-axis power feed controls.
-8-
AC
AD
AE
AF
AG
AH
AJ
AI
AE
AJ
AB. Power Feed Limit Switch: Stops table
movement when either of the switch side
plungers are pressed by limit stops.
AC. Limit Stop: Restricts table movement by its
positioning along front of table.
AD. Graduated Index Ring: Displays distance of
table travel in 0.001" increments, with one full
revolution equal to 0.200" of table travel.
AE. Feed/Jog Switch: In left (feed) position, it
enables power feed to operate normally.
While pressing switch to right (jog position),
table moves in selected direction until switch
is released.
In middle position ("0"), table movement is
disabled.
AF. Speed Dial: Controls speed of power feed.
Rotating dial clockwise causes table to move
faster.
AG. Direction Knob: Selects direction of table
movement. Middle position is neutral.
AH. Rapid Traverse Button: When pressed,
moves table at full speed when already in
motion.
AI. ON/OFF Button: Turns power feed ON and
OFF.
AJ. Circuit Breaker Reset Button: Resets inter-
nal circuit breaker if unit is overloaded and
shuts down.
Model G0796/G0797 (Mfd. Since 1/18)