Siemens SIMOTICS M-1PH818 Operating And Installation Instructions page 90

Main motors
Table of Contents

Advertisement

Commissioning
7.2 Checks to be carried out prior to commissioning
● Appropriately configured control and speed monitoring functions ensure that the the
● Any supplementary motor monitoring devices and equipment have been correctly
Converter operation
● If the design of the motor requires connection to a particular converter type, the rating plate
● The converter is correctly parameterized. The parameterization data is specified on the
● Any supplementary motor monitoring devices and equipment have been correctly
Roller bearing
● If the motor has been stored for more than two years in a dry, dust-free and vibration-free
Table 7-1
Type
1PH818.
1PH822.
1PH828.
External fan
● All external fans fitted are ready for operation and have been connected so that they rotate
● The flow of cooling air is not impeded.
Cooling water supply
● The cooling water supply is connected and ready for operation.
● The cooling water supply is switched on. The data can be found on the rating plate.
● Cooling water is available in the configured quality and quantity.
90
permissible speeds specified on the rating plate cannot be exceeded.
connected and are fully functional.
will contain corresponding additional information.
rating plate of the machine. Information about the parameters is available in the operating
instructions for the converter.
connected and are functioning correctly.
room, prepare for commissioning as follows:
– Replace the rolling-contact bearings on motors with lifetime lubrication.
– Replace the grease in motors with re-greasing system.
– If stored under less favorable conditions, the bearings or the grease must be replaced
after a storage period of approx. 18 months.
Minimum radial forces
in the direction specified.
Minimum radial force
4 kN
5 kN
9 kN
SIMOTICS M-1PH8 1PH818., 1PH822., 1PH828.
Operating Instructions 10/2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics m-1ph828Simotics m-1ph822

Table of Contents