Preparations for use

4.4 Ensuring cooling

Constituent
Operating pressure
Inlet temperature
Minimum cooling water inlet temperature
Anti-freeze protection / corrosion protection
Inhibitor NALCO 00GE056
Cooling water intake temperature
The maximum cooling water intake temperature is 30 °C.
NOTICE
Condensation for an excessively low cooling water intake temperature
If the temperature difference between cooling water and ambient temperature is greater than
5 K, this may result in condensation forming in the machine. This results in material damage.
● Make sure that the condensation can drain away freely.
● Adopt appropriate measures to achieve the required intake temperature of the cooling
● Alternatively, dry the ambient air.
4.4
Ensuring cooling
Note
Note also the technical data on the rating plates on the motor enclosure.
30
water.
Value
6 bar max.
< 30°C
T
> T
- 5 K
cooling water
ambient
20 ... 30 %
0.2 ... 0,25 %