● Make sure that the condensation can always drain away freely.
● The plug that has been inserted into the water drainage holes allows the condensation to
● If you have any questions, contact the Siemens Service Center (Page 161).
5.2.8

Putting the machine down

Requirements
The following preconditions must be satisfied before setting down the machine at the
installation location:
● The mating faces must be clean.
● The anti-corrosion protection paint has been removed from the mating faces, such as the
Setting down the machine
● Set down the machine slowly and carefully at the installation location to avoid any impact.
5.2.9
Roughly aligning the machine
Requirement
The transmission element such as a coupling half has already been pulled on.
Roughly aligning the machine
● For horizontal positioning, push the motor sideways across the foundation. When doing so,
SIMOTICS M-1PH8 1PH818., 1PH822., 1PH828.
Operating Instructions 10/2017
drain away. Do not remove the plug, otherwise the machine's degree of protection will be
affected.
machine mounting feet, flange, ...
There is no condensation present within the machine.
ensure that the axial position is maintained.
5.2 Lift the machine to where it will be mounted and position it
Mounting