M+Sf_Outc_R - Mitsubishi Electric MELSEC iQ-R Series Safety Function Block Reference

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

4.13

M+SF_OUTC_R

Overview
Item
Description
Function name
Output control
Functional overview
Control of a safety output with a signal from the standard application and a safety signal with optional startup inhibits.
Symbol
(1)
B: i_bActivate
(2)
B: i_bS_SafeControl
(3)
B: i_bProcessControl
(4)
B: i_bStaticControl
(5)
B: i_bS_StartReset
(6)
B: i_bS_AutoReset
(7)
B: i_bReset
Labels
■ Input labels
No.
Variable name
Data type
(1)
i_bActivate
Bit
(2)
i_bS_SafeControl
Bit*
(3)
i_bProcessControl
Bit
(4)
i_bStaticControl
Bit
(5)
i_bS_StartReset
Bit*
(6)
i_bS_AutoReset
Bit*
(7)
i_bReset
Bit
■ Output labels
No.
Variable name
Data type
(8)
o_bReady
Bit
(9)
o_bS_OutControl
Bit*
(10)
o_bError
Bit
(11)
o_wDiagCode
Word [signed]
M+SF_OUTC_R
o_bReady: B
o_bS_OutControl: B
o_bError: B
o_wDiagCode: W
Default value
Description
OFF
Activation of the safety FB.
For details, see the following.
Page 11 General Functions
OFF
Safety output signals from other FB libraries.
OFF: Safety output signals from other FB libraries are OFF.
ON: Safety output signals from other FB libraries are ON.
OFF
Control signal from the standard application.
OFF: Request to set i_bS_OutControl to OFF.
ON: Request to set i_bS_OutControl to ON.
OFF
Optional conditions for process control. (Constant)
OFF: Dynamic change at i_bProcessControl (OFF to ON) required after FB activation
or triggered safety function.
ON: No dynamic change at i_bProcessControl (OFF to ON) required after FB
activation or triggered safety function. If i_bProcessControl is set to ON, safety
output is set to ON.
OFF
Selection of a reset method for the activated (first time) safety FB.
For details, see the following.
Page 11 General Functions
OFF
Selection of a reset method for the input signal reset to ON.
For details, see the following.
Page 11 General Functions
OFF
Reset input.
For details, see the following.
Page 11 General Functions
Default value
Description
OFF
Status of whether the safety FB is activated or not.
For details, see the following.
Page 11 General Functions
OFF
Controls connected actuators.
OFF: Disable connected actuators.
ON: Enable connected actuators.
OFF
Error flag.
For details, see the following.
Page 11 General Functions
0
Diagnostic code.
For details, see the following.
Page 11 General Functions
(8)
(9)
(10)
(11)
4 SAFETY FB SPECIFICATIONS
4.13 M+SF_OUTC_R
4
87