Mitsubishi Electric MELSEC iQ-R Series Safety Function Block Reference page 66

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Typical timing diagram
■ For M+SF_MUTE2_R (i_bS_StartReset=OFF)
i_bActivate
i_bS_AOPD_In
i_bS_MutingSw_11
i_bS_MutingSw_12
i_bS_MutingLamp
i_dDiscTimeEntry
i_dMaxMutingTime
i_bMutingEnable
i_bS_StartReset
i_bReset
o_bReady
o_bS_AOPD_Out
o_bS_MutingActive
o_bError
0000H 8001H 8005H 8000H 8000H 8011H 8012H 8012H 8012H 8000H 8000H 8002H 8002H 8005H 8000H
o_wDiagCode
A program operation is suspended while the operation status of the CPU module is in STOP or PAUSE. Consequently,
measurement of the i_dDiscTimeEntry and i_dMaxMutingTime elapsed time is stopped.
Error behavior
In the event of an error, the output signals behave as listed below.
Output signal
o_bReady
o_bS_AOPD_Out
o_bS_MutingActive
o_bError
For the corrective actions, see the following.
Page 65 List of error codes
4 SAFETY FB SPECIFICATIONS
64
4.10 M+SF_MUTE2_R
Status
ON
OFF
OFF
ON

Advertisement