A replacement controller that is loaded with the same firmware load as the controller that is
being replaced (i.e.: controller for DS3 radio is replacing a DS3 radio controller) is
automatically rebooted and provisioned to match the module it is replacing. If the replacement
controller is for a different type of radio (i.e.; controller for a DS3 radio is being used to
replace a controller in a DS1 or OC3 radio), the controller alarm will flash when the
replacement module is installed in the shelf. The flashing alarm prompts the user that the
wrong firmware is installed.
e
Figure 5 - 14 Controller Module Installation (Sheet 2 of 4)
5-34
Note
Verify ala rm L E D i s n ot fl a shing and r eboot is
in prog ress . (re boo t i s i ndi c ated by all LE D s
f l a s h i n g i n p r o g r e s s i o n .
Is c ontro ller a l arm fl as hi n g?
Yes – Go to S tep
No
– I s reb oot i n pro gress?
Yes – Ve ri fy C ontr ol le r Ve r s i on on
botto m o f U S I s creen is latest.
Is lates t ve rsi o n of fi rmw a re display ed?
Ye s – S TO P. T hi s pro cedure i s complet e.
No
– D o y ou w a nt to upgrade to t he lat est
ve rsi o n?
Ye s – G o to ste p
No
– S top. Thi s procedur e is c om plet e.
.