a.
CONNECT SPECTRUM ANALYZER
TO RF MON CONNECTOR.
b. SET SPECTRUM ANALYZER CONTROLS.
CONTROL
INPUT ATTEN (dB)
CENTER FREQ
FREQ SPAN
RESOLUTION BW
VIDEO BW
REFERENCE LEVEL O dBm
SWEEP TIME
AMPLITUDE SCALE 10 dB/DIV
SPECTRUM
ANALYZER
c
Carefully adjust the spectrum analyzer to center the transmitter
spectrum.
As the spectrum analyzer's frequency span is reduced and the flat top of
the spectrum fills the spectrum analyzer display, it is extremely impor-
tant to keep the spectrum display (with carrier signal if any) centered
so that the carrier signal (if any) will remain visible as the span is
reduced.
PO SHELF
SETTING
10 dB
CHAN FREQ
(SEE FREQ LABEL
ON XMTR OR PA).
VALUE APPROXIMATELY
TWICE THE WIDTH OF
THE RF CHANNEL
BANDWIDTH
AUTO
AUTO
AUTO
PO SHELF
Note
XMT LVL
ADJ
PWR MON
FREQ CONT
XMT PWR
ALM
ON LINE
I CARR NULL
Q CARR NULL
TRANSMITTER
CHAN FREQ MHz
XTL FREQ MHz
XTAL
MON
RF
MON
RF
OUT
FREQ LABEL
MDR-1209
10/11/05
5-49