STATUS
DS3 Frame Loss
DS3 Buffer Spill
DS3 Degraded
DS3 AIS Detect
DS3 input data being written to elastic buffer
on DS3 I/O interface is a different rate than
the data being read from elastic buffer.
TRANSMITTER
STATUS
OC3 Input Online
OC3 LOS
OC3 LOF
OC3 AIS-L Detect
OC3 Degrade
Monday, April 09, 2001
Figure 5 - 5 Troubleshooting OC3/STM-1 Radio XMT Alarm
5-12
TRANSMITTER
A
Figure 5 - 4 Troubleshooting DS3 Radio XMT Alarms
A
B
1:58:29 PM
DS3 I/O INTFC cannot recover framing
from incoming DS3 signal or there is no
input signal. Is DS3 AIS Detect Alarm on?
B
Yes, troubleshoot upstream radios and
external MUX equipment.
No, check input signal. If input signal is
OK, replace DS3 I/O INTFC. If not,
troubleshoot external MUX equipment.
DS3 input to DS3 I/O INTFC has exceeded
provisioned BER threshold (high error
condition).Troubleshoot external MUX
equipment.
AIS (blue signal), inserted at MUX (external
to the radio) has been detected on XMT input
to DS3 I/O INTFC.
Troubleshoot external MUX equipment.
OC3/STM-1 INTFC cannot recover framing from
incoming OC3/STM-1 signal or there is no optical
input signal.
Is OC3/STM-1 AIS-L Detect alarm on?
Yes, troubleshoot upstream radios and external
MUX equipment.
No, check optical input signal. If optical input
signal is OK, replace OC3/STM-1 I/O INTFC. If not,
troubleshoot external MUX equipment.
AIS (blue signal), inserted at MUX (external to the
radio) has been detected on OC3/STM-1 input to
OC3/STM-1 I/O INTFC.
Troubleshoot external MUX equipment.
OC3/STM-1 input to OC3/STM-1 I/O INTFC has
exceeded provisioned BER threshold (high error
condition).
Troubleshoot external MUX equipment.