8.3 HOW TO CLEAR HISTORY DATA

A

Clearance of various logs after the Assys are replaced

Besides adjustment data, data on accumulated power-on time and logs on defective parts of the product are backed up.
Some of those data must be cleared after the Assys are replaced for service.
Clearance of those data can be performed in the ETC layer of the Factory menu or with RS232C commands.
Item
Hour-meter
Accumulated power-on time
Accumulated number of pulses emitted
Pulse-meter
B
Shutdown history
Causes and hour-meter values for the
of the panel
last eight shutdowns (SD) of the Panel
Causes and hour-meter values for the last
Power-down history
eight power-downs (PDs) of the Panel
Power-on counter
Relay-on count
Historical max. temperature of the
MAX TEMP
panel
Notes: • As the pulse-meter count is used for each correction function, the log must be cleared when the panel is replaced.
• After you clear the log, the unit must be turned off then back on again to reflect the cleared data for each correction
function. If any adjustment is required after clearing the log, be sure to turn the unit off then back on again before
C
adjustment.
(1) Clearance of logs, using the Factory menu
1 Turn on the power.
2 Enter the Panel Factory mode.
3 Clear the various logs, as shown in the figure below.
Note: The following example shows how to clear the PD log (PD INFO.). To clear other items, select each item you wish to
clear then perform the same procedures.
PANEL INFORMATION
D
Key Down 7th
ETC. (+)
SET
BACKUP DATA : NO OPRT
BACKUP DATA : NO OPRT
E
DIGITAL EEPROM : NO OPRT
PD INFO. < = > : NO OPRT
4 Turn off the power.
(2) Using the RS-232C commands
1 Turn on the power.
F
2 Issue the FAY command.
3 Issue the Delete command for a log you wish to clear.
4 Turn off the power.
164
1
2
Content
Panel
Must be cleared
Must be cleared
(mandatory)
Must be cleared
Must be cleared
No need to be
cleared
Must be cleared
Key Down
Key Down
Key Down
Right
PDP-5020FD
2
3
Clearing at the Replacement
POWER SUPPLY
Other parts
Unit
No need to be
No need to be
cleared
cleared
No need to be
No need to be
cleared
cleared
No need to be
No need to be
cleared
cleared
No need to be
No need to be
cleared
cleared
Must be cleared
No need to be
(mandatory)
cleared
Must be cleared
Must be cleared
PD INFO. < = > : CLEAR
3
4
Clearing method
Factory Menu
RS-232C
(ETC layer)
Commands
HR-MTR INFO.
CHM
PM/B1-B5
CPM
SD INFO.
CSD
PD INFO.
CPD
P COUNT INFO.
CPC
MAX TEMP.
CMT
SET (5 sec)