Qpf (Function Of The Panel); Qpm (Pulse Meter Value) - Pioneer PDP-5020FD Service Manual

Hide thumbs Also See for PDP-5020FD:
Table of Contents

Advertisement

5

[8] QPF (FUNCTION OF THE PANEL)

The command QPF is for acquiring the characteristic and the function setting value of the panel.
Command
Effective Operation
Format
Modes
[QPF]
Every Time
Data Arrangement
ECO
1
R-REVISE setting value
2
G-REVISE setting value
3
B-REVISE setting value
4
Reserved
5
ADDRESS L1,L2 setting value
6
ADDRESS L3,L4 setting value
7
ADDRESS U1,U2 setting value
8
ADDRESS U3,U4 setting value
9
Reserved
10
Streaking correction
11
Full-screen black display mode
12
Reserved
13
PANEL RX
14
PANEL RY
15
PANEL GX
16
PANEL GY
17
PANEL BX
18
PANEL BY
19
Reserved
20
Color sensor R coefficient
21
Color sensor G coefficient
22
Color sensor B coefficient
23
Reserved
CS
2 Byte

[9] QPM (PULSE METER VALUE)

The command QPM is for acquiring the accumulated pulse count.
Command
Effective Operation
Format
Modes
[QPM]
Every Time
Data Arrangement
ECO
1
Pulse meter B 1
2
Pulse meter B 2
3
Pulse meter B 3
4
Pulse meter B 4
5
Pulse meter B 5
CS
2 Byte
5
6
Function
Output of status
Data
Length Output Example
3 byte
QPF
1 byte
0
1 byte
0
1 byte
0
∗∗∗
3 byte
2 byte
01
2 byte
13
2 byte
32
2 byte
30
∗∗∗∗
4 byte
1 byte
1
1 byte
1
∗∗∗∗
4 byte
3 byte
512
3 byte
512
3 byte
512
3 byte
512
3 byte
512
3 byte
512
∗∗∗∗∗∗
6 byte
∗∗∗
3 byte
∗∗∗
3 byte
∗∗∗
3 byte
∗∗ to ∗∗
12 byte
2 byte
37
Function
Output of status
Data
Output Example
Length
3 byte
QPM
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
2 byte
E7
PDP-5020FD
6
7
Return data: 3 (ECO) + 69 (DATA) + 2 (CS) = 74 Byte
1: 2: 3: RGB-REVISE setting value
n
n: 0 to 7 (Level n)
5 to 8: ADDRESS α, β setting
n: 0 to 9 (Address α setting PHASE n)
nm
m: 0 to 9 (Address β setting PHASE m)
10: Streaking correction
0
OFF
n: 1 to 8 (Mode n)
n
11: Full-screen black display mode
0
OFF (In-phase SUS drive prohibition)
MODE1 (In-phase SUS drive permission)
1
Return data: 3 (ECO) + 40 (DATA) + 2 (CS) = 45 Byte
Note:
The minimum for a returned value of the pulse meter for each
block (B1-B2) is one million.
7
8
Remarks
Remarks
103
8
A
B
C
D
E
F