1
A

Overview

Preparation
Clearing of the hour meter and pulse meter
Aging with CMB MASK 01 (moving ramp)
displayed
Main flowchart (1)
Checking VOL OFFSET (min)
B
(RST MASK 09: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 18: Red 626)
OK
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
OK
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
OK
C
Main flowchart (2)
Checking VOL YNOFSA D (min)
(RST MASK 21: Red 1023+)
OK
D
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
OK
E
Adjustment completed
Replacement with the parts
for service
F
• Re-replacement of the panel
• Replacement of the DRIVE Assy
166
1
2
Recovery flowchart (1-1)
Checking VOL OFFSET (min)
(RST MASK 09: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 18: Red 626)
OK
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
OK
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
NG
OK
NG
Recovery flowchart (1-2)
Checking VOL OFFSET (min)
(RST MASK 18: Red 626)
OK
NG
Recovery flowchart (1-3)
Checking VOL OFFSET (max)
(RST MASK 19: Green 626)
NG
OK
Recovery flowchart (1-4)
Checking VOL OFFSET (max)
(RST MASK 20: Blue 626)
OK
Checking VOL OFFSET (min)
(RST MASK 09: Pink)
OK
Recovery flowchart (2-1)
Checking VOL YNOFSA D (min)
NG
(RST MASK 21: Red 1023+)
OK
NG
Recovery flowchart (2-2)
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
OK
NG
Recovery flowchart (2-3)
NG
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
OK
Recovery flowchart (2-4)
Checking VOL YNOFSA D (max)
(RST MASK 14: Cyan 120)
OK
Checking VOL YNOFSA D (min)
(RST MASK 21: Red 1023+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 22: Green 1023+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 23: Blue 1023+)
OK
PDP-5020FD
2
3
Range of margin measuring
Read the voltage within the hysteresis (stricter value).
NG
V
Erroneous discharge
NG
Read the voltage
within this range.
NG
Erroneous discharge
NG
Definition of limits for the voltage margins
(abnormal lit/dead cells)
NG
Abnormal lit cells:
• Five or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
Abnormal dead cells
• Fifteen or fewer abnormal cells on the whole screen
NG
• Two or fewer abnormal cells within a radius of 1 cm
∗: Abnormal cells visually recognizable at a distance of
1 meter from the panel must be counted.
∗: Cells displayed abnormally for less than one second
NG
are not counted as abnormal cells.
NG
Definition of tones for the measuring
signals
NG
FHD signal (1920*1080)/Video 60-Hz sequence
/Dither: ON, L dither: ON, noise: OFF
Pink
RST MASK 09 (R 1023 /G 626 /B 1023)
Cyan 120
RST MASK 14 (R 0 /G 120 /B 120)
NG
Red 626
RST MASK 18 (R 626 /G 0 /B 0)
Green 626
RST MASK 19 (R 0 /G 626 /B 0)
Blue 626
RST MASK 20 (R 0 /G 0 /B 626)
Red 1023+
RST MASK 21 (R 1023 /G 120 /B 120)
Green 1023+
RST MASK 22 (R 120 /G 1023 /B 120)
NG
Blue 1023+
RST MASK 23 (R 120 /G 120 /B 1023)
NG
Interlocked settings for Voltages Vyknofs1/3/4
For the 9th-generation PDPs, interlocked setting for
Voltages Vyknofs1/3/4 is available on the Factory menu or
with RS232C commands, for easier adjustment. Therefore,
in the adjustment flowchart, the interlocked setting function
is used. (Individual setting for each adjustment value is
NG
also possible, as in the conventional setting methods.
Set Voltage
Factory Menu Command
NG
Vyknofs1 individual
Vyknofs3 individual
Vyknofs4 individual
NG
Vyknofs1,3,4 interlocked
Note:
NG
• The initial value for the interlocked setting value is 128,
including for factory preset values.
• See "[3] DRIVE ASSY" of "5.2 DIAGNOSIS FLOWCHART
OF FAILURE ANALYSIS" for calculation of actually used
voltage values.
3
4
Adjustment
value m+1
Adjustment
value m
No erroneous
discharge
Adjustment
value n
Adjustment
value n-1
VOL YNOFS1 D
[V1F]
VOL YNOFS3 D
[V3F]
VOL YNOFS4 D
[V4F]
VOL YNOFSA D
[VYF]
4