1
A

[10] QPD (POWER DOWN LOGS)

The command QPD is for acquiring data from the 8 latest power-down (PD) logs.
Command
Effective Operation
Format
[QPD]
Every Time
Data Arrangement
ECO
B
1
Latest "1st PD" data
2
Latest "2nd PD" data
3
Data from the hour meter for the latest PD
4
Second latest "1st PD" data
5
Second latest "2nd PD" data
6
Data from the hour meter for the second latest PD
7
Third latest "1st PD" data
8
Third latest "2nd PD" data
9
Data from the hour meter for the third latest PD
C
10
Fourth latest "1st PD" data
11
Fourth latest "2nd PD" data
12
Data from the hour meter for the fourth latest PD
13
Fifth latest "1st PD" data
14
Fifth latest "2nd PD" data
15
Data from the hour meter for the fifth latest PD
16
Sixth latest "1st PD" data
17
Sixth latest "2nd PD" data
18
Data from the hour meter for the sixth latest PD
19
Seventh latest "1st PD" data
D
20
Seventh latest "2nd PD" data
21
Data from the hour meter for the seventh latest PD
22
Eighth latest "1st PD" data
23
Eighth latest "2nd PD" data
24
Data from the hour meter for the eighth latest PD
CS
2 Byte
E
F
104
1
2
Modes
Output of status
2
3
Function
Return data: 3 (ECO) + 80 (DATA) + 2 (CS) = 85 Byte
Data
Output Example
Length
3 byte
QPD
1 byte
A
1 byte
2
8 byte
00010020
1 byte
E
1 byte
9
8 byte
00008523
1 byte
4
1 byte
3
8 byte
00004335
1 byte
2
1 byte
0
8 byte
00000945
1 byte
4
1 byte
0
8 byte
00000715
1 byte
A
1 byte
2
8 byte
00000552
1 byte
A
1 byte
0
8 byte
00000213
1 byte
D
1 byte
0
8 byte
000001A7
2 byte
27
PDP-5020FD
3
4
Remarks
" PD data
0
No PD
2
P-POWER
3
SCAN
4
SCN-5V
6
Y-DCDC
7
Y-SUS
8
Address
A
X-DCDC
B
X-SUS
C
DIGI-DCDC
F
UNKNOWN
4

Hide quick links: