Pioneer PRO-141FD Service Manual page 202

Flat panel display
Hide thumbs Also See for PRO-141FD:
Table of Contents

Advertisement

1
A
Recovery flowchart (2-1)...Changing the VOL YNOFSA D setting
[From the Main flowchart (2)]
RST MASK 19 (Green 718+)
Gradually increase the VOL YNOFSA D value until disappear the
discharge (dead cell).
The tentative setting value of VOL YNOFS1 D + current setting
value of VOL YNOFSA D must be 205 or less.
B
Tentative setting value of VOL YNOFS1 D
+ current setting value of VOL YNOFSA D
Display RST MASK 18 (Red 626+). / [MKR S18]
[To the Recovery flowchart (2-2)]
C
Recovery flowchart (2-2)...Changing the VOL YNOFSA D setting
[From the Main flowchart (2) / Recovery flowchart (2-1)]
RST MASK 18 (Red 626+)
Gradually increase the VOL YNOFSA D value until disappear the
discharge (dead cell).
D
The tentative setting value of VOL YNOFS1 D + current setting
value of VOL YNOFSA D must be 205 or less.
Tentative setting value of VOL YNOFS1 D
+ current setting value of VOL YNOFSA D
Display RST MASK 23 (Magenta 169). / [MKR S23]
E
Set VOL YNOFSA D to the current setting value plus 44. / [VYF ∗∗∗]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Set VOL YNOFSA D to the current setting value minus 13. / [VYF ∗∗∗]
Determine the current VOL YNOFSA D setting value as the final value.
F
[To the Main flowchart (2)]
202
1
2
> 203?
No
> 203?
No
No
PRO-141FD
2
3
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
3
4
4