1
A
Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 19 (Green 718+). / [MKR S19]
Set VOL YNOFSA D to the tentative setting value 096. / [VYF 096]
B
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 18 (Red 626+). / [MKR S18]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
C
Display RST MASK 23 (Magenta 169). / [MKR S23]
Set VOL YNOFSA D to the tentative setting value 140. / [VYF 140]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
D
Determine the tentative setting value for VOL YNOFSA D as the final value.
[Adjustment completed]
Note:
E
Make sure that the following values become the final setting values.
VOL SUS *1
VOL XPOSF2 *1
VOL OFFSET
VOL YNOFS1 D *1
VOL RST P *1
VOL YNOFS3 D *1
VOL XPOFS1 *1
VOL YNOFS4 D *1
VOL YNOFS4 A
*1: The tentative setting value becomes the final value.
F