Pioneer PRO-141FD Service Manual page 200

Flat panel display
Hide thumbs Also See for PRO-141FD:
Table of Contents

Advertisement

1
A
Display RST MASK 03 (Green). / [MKR S03]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
B
Set VOL OFFSET to the current setting value minus 67. / [VOF ∗∗∗]
Determine the current VOL OFFSET setting value as the final value.
[To the Main flowchart (1)]
C
Recovery flowchart (1-3)...Changing the VOL OFFSET setting
[From the Main flowchart (1) ]
RST MASK 02 (Red)
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 101 or greater.
D
Current VOL OFFSET < 107?
Display RST MASK 03 (Green). / [MKR S03]
[To the Recovery flowchart (1-4)]
E
F
200
1
2
A
No
No
PRO-141FD
2
3
Yes
Replacement of abnormal circuits or
re-replacement of the panel required
Yes
Replacement of abnormal circuits or
re-replacement of the panel required
3
4
4