Details Of Rs-232C And Ip Commands - Pioneer PRO-141FD Service Manual

Flat panel display
Hide thumbs Also See for PRO-141FD:
Table of Contents

Advertisement

5

5.9 DETAILS OF RS-232C AND IP COMMANDS

[1] QS2 (PANEL OPERATION DATA)
The command QS2 is for acquiring data on the panel's operational information.
Command
Effective Operation
Format
Modes
[QS2]
Every Time
Data Arrangement
ECO
1
Notify of the standby operation transition
2
Adjustment flag of the main unit
3
Adjustment-data backup flag
4
"1st PD" data
5
"2nd PD" data
6
Color sensor data
7
Reserved
8
Temperature data (TEMP 1)
9
SD data
10
SD subcategory data
11
Operation status induced by SD
12
Reserved
13
HOUR METER
14
MASK indication
15
Still picture detection
16
SCAN protection detection
17
Panel crack detection
18
Address emergency detection
19
Reserved
CS
2 Byte
1: Power supply status
P
During power ON
Shifting to Passive
0
Standby is not
possible.
Shifting to Passive
1
Standby is possible.
2: Adjustment flag of
the main unit
0
Adjustment completed
Adjustment not
1
completed
3: Adjustment-data
backup flag
0
Adjustment completed
1
Adjustment not completed
5
6
Function
Output of status
Data
Output Example
Length
3 byte
QS2
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
2 byte
3 byte
128
1 byte
1 byte
1 byte
∗∗∗
3 byte
00000259
8 byte
1 byte
1 byte
1 byte
1 byte
1 byte
∗∗∗∗
4 byte
4A
2 byte
4, 5: PD data
0
No PD data
2
POWER
3
SCAN
4
SCN-5V
6
Y-DCDC
7
Y-SUS
8
ADRS
A
X-DCDC
B
X-SUS
C
DIG-DCDC
F
UNKNOWN
6: Color sensor data
-
Function OFF (including standby)
0
Normal
1
Hardware connection is not completed
2
Data mismatching
PRO-141FD
6
7
Return data: 3 (ECO) + 34 (DATA) + 2 (CS) = 39 Byte
9: SD data
0
No SD
1
1
SQ_LSI
0
2
MDU-DEVICE
0
3
RST2
0
4
Panel temperature
0
0
10-1: SD subcategory (SQ_LSI)
∗∗
0
No SD-Sub data
1
Communication error
0
2
Drive stop
0
3
BUSY
0
4
Version mismatching (H/S)
5
Version mismatching (H/M)
6
Version mismatching (H/I)
0
10-2: SD subcategory (MD-DEVICE)
0
0
No SD-Sub data
0
1
EEPROM
0
2
BACKUP
0
3
DAC
10-3: SD subcategory
(Panel temperature)
0
No SD-Sub data
1
Panel high temperature
2
Panel low temperature
11: Operation status
induced by SD
0
Normal
1
Relay-off completed
During warning
2
indication
14: MASK indication
0
MASK-OFF
1
MASK-ON
15 to 18: Detection of Each Protection function
0
Normal operation
1
At detection of protection operation
7
8
Remarks
103
8
A
B
C
D
E
F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: