ELECTRIC WIRING

ELECTRICAL WIRE RESISTANCE

AWG
Nominal mm²
20
18
16
14
12
10
8
6
4
2
1
0 (1/0)
00 (2/0)
000 (3/0)
0000 (4/0)
Wiring voltage drop should not exceed 5% [0.05] x 12 Volts = 0.6 Volts.
Voltage Drop = Current [Amps] x Length of Wire [Feet] x Resistance per Foot Ω
Example:
Current draw of 100 Amps x 3 feet of 4 AWG wire
100 Amps x 3 Feet x 0.000270 = 0.08 Volts [Voltage Drop]
13-4
Metric
Ohms / Foot
Resistance
0.5
0.009967
0.8
0.006340
1.25
0.004359
2
0.002685
3
0.001704
5
0.001073
8
0.000707
15
0.000421
20
0.000270
30
0.000158
40
0.000130
50
0.000103
60
0.000087
85
0.000066
100
0.000051
Electrical Wire Resistance