Wire And Cable Access - Trane TR200 Operating Instructions Manual

Option panel
Hide thumbs Also See for TR200:
Table of Contents

Advertisement

ID
Definition
24V
Option panel 24 Vdc SMPS
CB1
Main Circuit breaker
DS1
Main or line disconnect
DS2
Drive disconnect
DF15
Main fused disconnect
DV1
VFD output motor filter
F12
T1 secondary fuse
F13
T1 primary fuse
F15
Line or main fuse
F16
Drive fuse
GD
Ground terminal
LR1
VFD input line reactor
M1
VFD input contactor
M2
VFD output contactor
M3
Bypass contactor
M4
Motor 1 contactor
Table 3.5
ID
Definition
M5
Motor 2 contractor
MT1
Motor 1 connection terminal
OL1
Overload for motor 1
OL2
Overload for motor 2
PL2
Bypass indicator light
S1
Bypass selector switch
S103
Auto bypass selection switch 4 position switch used to setup auto bypass on EMB2 control op-
S2
CMS selector switch
T1
120 Vac control transformer
T3
120 Vac control transformer
TB1
Terminal Block 1
VFD
Variable frequency drive
X55
Customer terminal block
X56
Customer terminal block
X58
Customer terminal block
Table 3.6

Wire and Cable Access

Determine the wiring path through the option panel enclosure. See the mechanical layout drawing lo-
cated on the inside cover of the unit for locations to connect power and motor wiring.
Removable access covers are provided for cable connections (see figure
move access covers prior to drilling holes to prevent metal shavings from damaging internal
electronic components.
For some units, access holes are provided for input power, motor leads, and control wiring.
TR200 Option Panel Operating Instructions
Supply 24 Vdc control power to option panel for internal use only
Provide isolation between option panel and current protection for
incoming mains
Provide isolation between option panel and mains
Provide isolation between VFD and line voltage
Provide isolation between option panel and mains
Output filter to provide filtering for PWM drive output wave form
Current protection for internal 120 Vac control circuit
Current protection for line side of 120 Vac internal control trans-
former
Provide current protection to option panel
Provide current protection to drive
Customer connection for power grounds to mains and motor
Input reactor to provide additional input impeadance to drive
Provide isolation between VFD and line voltage
Provide isolation between VFD and motor
Provide line voltage to motor
Used to select motor 1 operation
Used to select motor 2 operation
Provides termination point for motor leads in option panel
Provide overload protection to motor when running in bypass
Provide overload protection to motor when running in bypass
Provides indication when motor is in bypass mode
Operator interface for bypass mode selection on electromechani-
cal bypass
tion
Operator interface for contactor motor selection
Provide internal 120 Vac supply
Provide customer 120 Vac supply
Customer bypass control connections for ECB-CMS and EMB0
control option
Provide variable frequency and voltage to AC motor
Customer control connection terminal block on EMB1 and EMB2
control option
Customer control connection terminal block on EMB1 and EMB2
control option
Customer control connection terminal block on EMB2 control op-
tion
Installation
Function
Function
Conduit Entry Diagrams
). Re-
19