Step
4.
(Optional.) Enable the
cross-connect group.
5.
Create a cross-connect and
enter cross-connect view.
6.
Set an MTU for the PW.

Configuring a PW

Configuring a PW class
You can configure PW attributes such as the PW data encapsulation type and enable control word in
a PW class. PWs with the same attributes can use the same PW class.
To configure a PW class:
Step
1.
Enter system view.
2.
Create a PW class and enter
PW class view.
3.
(Optional.) Enable control
word.
4.
(Optional.) Specify the PW
data encapsulation type.
5.
(Optional.) Enable sequencing
for both incoming and outgoing
packets on the PW.
Configuring a static PW
Step
1.
Enter system view.
2.
Enter cross-connect group
view.
3.
Enter cross-connect view.
4.
Configure a static PW, and
enter cross-connect PW
view.
5.
Set the expected bandwidth
for the PW.
Command
undo shutdown
connection connection-name
mtu size
Command
system-view
pw-class class-name
control-word enable
pw-type { ethernet | vlan }
sequencing both
Command
system-view
xconnect-group group-name
connection connection-name
peer ip-address pw-id pw-id
in-label label-value out-label
label-value [ pw-class class-name
| tunnel-policy
tunnel-policy-name ] *
bandwidth bandwidth-value
400
Remarks
By default, the cross-connect
group is enabled.
By default, no cross-connects
exist.
The default MTU is 1500 bytes.
The two PEs on an LDP PW must
have the same MTU configured
for the PW. Otherwise, the PW
cannot come up.
Remarks
N/A
By default, no PW classes exist.
By default, control word is
disabled.
By default, the PW data
encapsulation type is VLAN.
By default, sequencing is
disabled.
Remarks
N/A
N/A
N/A
By default, no static PWs exist.
By default, the expected value is
10000000 kbps.

Advertisement