IBM xSeries 445 Type 8870 Option Installation Manual page 77

Hide thumbs Also See for xSeries 445 Type 8870:
Table of Contents

Advertisement

One server with two SMP Expansion Modules
If your server has two SMP Expansion Modules installed complete the following
steps. For information about cabling the RXE Management Ports, see "RXE
Management Port cabling" on page 69.
1. Remove the protective covers from the connectors on the ends of the cables.
Protective cover
Figure 63. RXE Expansion cable with protective cover
2. Using an RXE Expansion cable, connect one end of the cable to RXE
Expansion Port B on the server.
RXE Expansion Port B
RXE Expansion Port A
Figure 64. RXE Expansion port cabling a server with two SMP Expansion Modules
3. Connect the opposite end of the cable to an RXE Expansion Port on the remote
I/O enclosure.
Notes:
a. When two SMP Expansion Modules are installed, both of the RXE
Expansion ports are active.
b. To increase reliability connect a second RXE Expansion cable from the
server RXE Expansion Port A to the remote I/O enclosure RXE Expansion
Port B. This will create a redundant data path if either of the two cables fail.
4. Go to "One server" on page 69 in the "RXE Management Port cabling" section
and complete the procedure.
xSeries 445
RXE-100
Chapter 2. Installing options
65