Ariston M1 10L FF Service Manual page 53

Domestic gas instantaneous water heater m1/m2 fi7/gi7s
Table of Contents

Advertisement

between air intake of the machine and the
wall is less than 10cm, which causes
insufficient oxygen supply
Insufficient
air
14
combustion: small fan throttle
Insufficient
air
15
combustion::一
Small aperture of the first wind guard
Insufficient
air
16
combustion::
Low rotary speed of fan
Too
much
17
combustion: Large fan throttle
Too
much
18
combustion:
Large aperture of the first wind guard
Too
much
19
combustion or high air flow speed: high
rotary speed of fan
20
Low water pressure
21
Unstable water pressure
22
Improper use of mixing water valve
23
Flue pipe is blocked
24
Downdraft
25
Seizure of anti-downdraft device
Block caused by carbon deposit on cooling
26
fin of heat exchanger
Burnt out and block of cooling fin on heat
27
exchanger
28
Flame rows on igniter are blocked
29
Blocked nozzles
Non-conforming installation of flue pipe: too
30
many
elbows/long
exhaust outlet
31
Carbon deposit on sensing probe
32
Sensing probe is broken
33
Bad contact of sensing probe
Distance between sensing probe and flame
34
row is too large
35
Fault of igniter
Parameter of main control board is on the
36
low side
Technical Manual for DGI
volume
required
volume
required
volume
required
air
volume
required
air
volume
required
air
volume
required
flue
pipe/setting
- 53 -
by
Adjust
by
Replace or adjust
by
Apply proper measures as
per specific situation
by
Adjust
by
Replace or adjust
by
Apply proper measures as
per specific situation
Explain and give directives
Explain and give directives
Explain and give directives
Clean
Explain or carry out
strengthening measures
Adjust or replace
Clean or replace
Replace
Clean or replace
Clean
of
Re-installation
Clean
Replace
Adjust
Adjust
Replace
Adjust