Fi7/Gi7S - Ariston M1 10L FF Service Manual

Domestic gas instantaneous water heater m1/m2 fi7/gi7s
Table of Contents

Advertisement

1.7.2 Fi7/Gi7S

1) Hot-water flow-out
Press down the power supply button on the control panel to turn LCD display on. Panel flashes
to show 42℃ and indicates real-time water temperature in 3 seconds flashing. (Initial
temperature setting, i.e. ex-works setting is 42℃.)
Open the hot-water faucet. Burner ignites automatically and hot water flows out. (For the initial
running, open and close the hot-water faucet repeatedly till water heater ignites because of air
residue in the gas pipe.)
Recommend opening the hot-water faucet to the larger extent. Otherwise ignition may be
impossible or there is flameout during the cold-water mixing process.
The water heater adopts safety and energy-saving new technology. Gas is disconnected
automatically after water heater continuously works for 30±3min. Then burner is extinguished. If
continuous use is required, re-ignition is available just by closing the hot-water faucet for
several seconds before re-start.
2) Water temperature adjustment
If water heater is connected with both control panel and wireless bathroom remote controller,
Technical Manual for DGI
- 21 -