set sntp poll-interval

Use this command to set the poll interval between SNTP unicast requests.
Syntax
set sntp poll-interval interval
Parameters
 interval
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the SNTP poll interval to 30 seconds:
C2(su)->set sntp poll-interval 30

clear sntp poll-interval

Use this command to clear the poll interval between unicast SNTP requests.
Syntax
clear sntp poll-interval
Parameters
None.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear the SNTP poll interval:
C2(su)->clear sntp poll-interval
Specifies the poll interval in seconds. Valid values are 16 to 16284. 