Fourth Edition • First Printing
Introduction
Bi-Energy models can be operated with or without
the engine running.
Starting the Engine
1 At the ground controls, turn the key switch to
the desired position.
2 Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
on position.
3 Move the engine start toggle switch
to either side. If the engine fails to
start or dies, the restart delay will
disable the start switch for 3
seconds.
If the engine fails to start after 15 seconds of
cranking, determine the cause and repair any
malfunction. Wait 60 seconds before trying to start
again.
In cold conditions, hold the glow plug switch to
either side for 3 to 5 seconds and then start the
engine.
In extreme cold conditions, 20°F / -6°C and below,
hold the glow plug switch to either side for 10
seconds and then start the engine. Warm the
engine (use low idle) for 5 minutes to prevent
hydraulic system damage.
Emergency Stop
Push in either the ground or platform red
Emergency Stop button to the off position to stop
all machine functions.
Repair any function that operates when the red
Emergency Stop button is pushed in.
Selecting and operating the ground controls will
override the platform red Emergency Stop button.
Part No. 114358
Z-45/25 DC • Z-45/25J DC • Z-45/25 Bi-Energy • Z-45/25J Bi-Energy
Operating Instructions
Auxiliary Controls
Use auxiliary power if the primary power source
fails.
1 Turn the key switch to ground or platform
control.
2 Pull out the red Emergency Stop button to the
on position.
3 Press down the foot switch when operating the
auxiliary controls from the platform.
4 Simultaneously hold the auxiliary
power switch on and activate the
desired function.
The drive function will not operate with auxiliary
power.
Operation from Ground
1 Turn the key switch to ground control.
2 Pull out the red Emergency Stop
button to
the on position.
To Position Platform
1 Hold the function enable switch to
either side.
2 Move the appropriate toggle switch according to
the markings on the control panel.
Drive and steer functions are not available from the
ground controls.