Genie Z-45 Operator's Manual page 29

Dc power bi-energy power boom lifts
Hide thumbs Also See for Z-45:
Table of Contents

Advertisement

Fourth Edition • First Printing
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: The beacon (if equipped) should flash.
4 Bi-Energy models: Start the engine. See
Operating Instructions section.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine (if equipped) should turn off.
6 Activate each machine function control handle
or toggle switch.
Result: No functions should operate.
7 Pull out the red Emergency Stop button to
the on position.
Test Machine Functions and Descent Alarm
8 Do not hold the function enable
switch to either side. Attempt to
activate each boom and platform
function toggle switch.
Result: All boom and platform
functions should not operate.
9 Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
should sound while the boom is lowering.
Part No. 114358
Z-45/25 DC • Z-45/25J DC • Z-45/25 Bi-Energy • Z-45/25J Bi-Energy
Test the Tilt Sensor
10 Pull out the platform red Emergency Stop button
to the on position. Turn the key switch to
platform control.
11 Open the turntable cover on the
side opposite the ground controls
and locate the tilt sensor.
12 Press down one side of the tilt
sensor.
Result: The alarm, located in the
platform, should sound.
Test Auxiliary Controls
13 Turn the key switch to ground control.
14 Pull out the red Emergency Stop button to the
on position.
15 Simultaneously hold the auxiliary
power switch on and activate each
boom function toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
Operator's Manual
Inspections
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z-45jZ-25Z-25j

Table of Contents