The following table provides a list of the fields in the Advanced tab of the
Module Configuration dialog box and their descriptions:
Avaya C360 Manager User Guide
Table 3-4. Module Configuration Fields - Advanced Tab
Field
BUPS Module Type
BUPS Module CS
Cascading Up Mon.
Cascade Down Mon.
Internal PS Status
BUPS Status
LLDP Mode
LLDP Tx Interval
Description
The type of BUPS (BackUp Power Supply)
module in the selected module.
The version of the BUPS (BackUp Power
Supply) module. The version is updated
whenever there is a functional modification to
the module.
Determines if the devices in the system are
monitored cascading up. The possible values
are:
• Enable - Monitors devices in the
network cascading up. If the connection
is lost, the system reports a error.
• Disable - Does not monitor devices in
the network cascading up. If the
connection is lost, the system does not
report a error.
Determines if the devices in the system are
monitored cascading down. The possible
values are:
• Enable - Monitors devices in the
network cascading down. If the
connection is lost, the system reports a
error.
• Disable - Does not monitor devices in
the network cascading down. If the
connection is lost, the system does not
report a error.
The operating status of the primary power
supply.
The operating status of the BUPS.
The status of Link Layer Discovery Protocol
(LLDP) Mode on the device:
• Enable - Use LLDP Mode.
• Disable - Do not use LLDP Mode.
The amount of time between packet
transmissions on the device.
Device Configuration
29