Chevrolet 1973 Overhaul Manual page 214

Passenger car and light duty truck
Table of Contents

Advertisement

material, and also a piece of tape over the shaft at
the slip ring end.
CAUTION: Brushes may drop onto the rbtor
shaft and become contaminated with bearing
lubricant. Clean brushes prior to installing with
a non- toxic cleaner such as trichlorethylene or
a soft dry cloth.
4. Remove the stator lead attaching nuts and separate
stator from end frame.
NOTE: At this point, with the two end
frames separated the stator disconnected and
the rotor removed electrical checks of the
rotor, rectifier bridge, stator and diode trio
brush lead clip may be made without further
disassembly. Refer to the specific checks as
outlined in this section.
5. Remove screw attaching diode trio to brush holder
assembly and remove diode trio from end frame
(fig. 1C).
NOTE: Diode trio may be checked for a
grounded brush lead clip at this point. Refer
to diode trio checks.
6. Remove the rectifier bridge attaching screw and the
"BAT" terminal screw, and disconnect the capacitor
lead. Remove rectifier bridge from the end frame.
7. Remove two attaching screws, and remove brush
holder and regulator assemblies.
NOTE: Two insulators are assembled over
the top of the brush retaining clips and the
two screws have special insulating sleeves
over the screw body.
8. Remove retaining screw and capacitor from end of
frame (fig. 6C).
9. Remove slip ring end fram e bearing (if necessary).
Refer to bearing replacement covered in this
section.
10. Remove pulley retaining nut and slide washer,
pulley, fan and spacer from shaft.
a. Single groove pulley—place 15/16" box wrench
on the shaft nut and insert a 5/16" alien wrench
into the shaft end hole to hold the shaft while
removing the nut (fig. 2C).
b. Double groove pulley—place a 15/16" socket
(with wrench flats on the drive end or use
adapter J-21501 and a box wrench on the pulley
retaining nut, insert a 5/16" alien wrench
through the socket and adapter into hex hole in
the shaft to hold the shaft while removing the
nut.
11. Remove rotor and spacers from the drive end
frame assembly.
12. Remove drive end fram e bearing retainer plate
screws, plate, gasket, bearing, and slinger from end
frame (if necessary).
EN G IN E ELECTRICAL
Fig. 2C-Removing Pulley
CLEANING AND INSPECTIO N
With generator completely disassembled the components
should be cleaned and inspected. Be sure testing
equipment is in good working order before attempting to
check the generator.
1. Wash all metal parts except stator and rotor
assemblies.
2. Clean bearings and inspect for sealing, pitting or
roughness.
3. Inspect rotor slip rings, they may be cleaned with
400 grain polishing cloth. Rotate rotor for this
operation to prevent creating flat spots on slip
rings.
4. Slip rings which are out of round may be trued in a
lathe to .001" maximum indicator reading. Remove
only enough m aterial to make the rings smooth and
concentric. Finish with 400 grain polishing cloth
and blow dry.
5. Slip rings are not replaceable—excessive damage
will require rotor assembly replacement.
6. Inspect brushes for wear. If they are worn halfway,
replace. Inspect brush springs for distortion or
weakening. If brushes appear satisfactory and move
freely in brush holder, springs may be reused.
TESTING
Where specified, conduct the following tests using an
ohmmeter with a 1-1/2 volt cell and use the lowest range
scale for the readings.
Rotor Field Winding Checks (fig. 3C )
The rotor may be checked electrically with a 110-volt test
lamp or an ohmmeter.
Open Circuit
Connect one test lamp or ohmmeter lead to each slip
6Y-9
CHASSIS OVERHAUL MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents