HP ProLiant ML30 Gen9 Maintenance And Service Manual page 60

Hide thumbs Also See for ProLiant ML30 Gen9:
Table of Contents

Advertisement

CAUTION: Do not overtighten the screws as this might damage the board, connectors, or
screws and voids the warranty of the board.
Install the heatsink:
10.
Position the heatsink using the guide pin on the processor backplate.
a.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
b.
Finish the installation by completely tightening the screws in the same sequence.
c.
CAUTION: When returning a damaged system board to Hewlett Packard Enterprise, always
install all processor socket covers to prevent damage to the processor sockets and system
board.
Install the processor socket cover on the failed system board.
11.
Install the rear system fan.
12.
Connect all cables disconnected from the failed system board.
13.
Install the air baffle.
14.
Install the access panel.
15.
Return the server to an upright position.
16.
Install and lock the tower bezel.
17.
Removal and replacement procedures 60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents