9-5-5

3323 hex: 3rd Notch Filter

Sets the 3rd resonance suppression notch filter.
Sub-
Index
index
Object name
(hex)
(hex)
3323
---
3rd Notch Filter
00
Number of
entries
01
Enable
02
Frequency
03
Q-value
04
Depth
81
Enable Display
82
Frequency Dis-
play
83
Q-value Display
84
Depth Display
Subindex 01 hex: Enable
• Selects whether to enable or disable the 3rd notch filter function.
Description of Set Values
Set value
0
1
Subindex 02 hex: Frequency
• Sets the notch frequency of the 3rd resonance suppression notch filter.
Subindex 03 hex: Q-value
• Sets the Q-value of the 3rd resonance suppression notch filter.
• Decreasing the setting value widens the notch width.
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Setting
Default
Unit
range
setting
---
---
---
---
84 hex
0 to 1
---
500 to
0.1 Hz
50,000
50,000
50 to
0.01
140
1,000
0 to 60
dB
---
---
---
0.1 Hz
---
0.01
---
dB
Disabled
Enabled
9 Details on Servo Parameters
Data
attri-
Size
Access
bute
---
---
---
---
1 byte
(U8)
0
A
4 bytes
(INT32)
A
4 bytes
(INT32)
A
4 bytes
(INT32)
60
A
4 bytes
(INT32)
---
---
4 bytes
(INT32)
---
---
4 bytes
(INT32)
---
---
4 bytes
(INT32)
---
---
4 bytes
(INT32)
Description
PDO
Complete
Modes of
map
access
operation
---
---
Possible
RO
---
---
RW
---
---
RW
---
---
RW
---
---
RW
---
---
RO
---
---
RO
---
---
RO
---
---
RO
---
---
---
---
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
csp, csv,
cst, pp,
pv, hm
9