HP FlexFabric 5930 Series Command Reference Manual
HP FlexFabric 5930 Series Command Reference Manual

HP FlexFabric 5930 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 5930 Series:
Table of Contents

Advertisement

HP FlexFabric 5930 Switch Series
SPB

Command Reference

Part number: 5998-7791a
Software version: Release 241x
Document version: 6W102-20151210

Advertisement

Table of Contents
loading

Summary of Contents for HP FlexFabric 5930 Series

  • Page 1: Command Reference

    HP FlexFabric 5930 Switch Series Command Reference Part number: 5998-7791a Software version: Release 241x Document version: 6W102-20151210...
  • Page 2 The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    Contents SPBM commands ························································································································································· 1   ap-mode ·········································································································································································· 1   area-authentication send-only ······································································································································· 1   area-authentication-mode ·············································································································································· 2   b-vlan ··············································································································································································· 3   bandwidth-reference ······················································································································································ 4   bridge-priority ································································································································································· 5   circuit-cost ······································································································································································· 5   control-address ······························································································································································· 6   display l2vpn minm connection ···································································································································· 7  ...
  • Page 4 ······································································································································································· 75   vsi 76   xconnect vsi ································································································································································· 77   Support and other resources ····································································································································· 79   Contacting HP ··································································································································································· 79   Subscription service ···················································································································································· 79   Related information ··························································································································································· 79   Documents ··································································································································································· 79   Websites ······································································································································································ 79  ...
  • Page 5: Spbm Commands

    SPBM commands ap-mode Use ap-mode to configure the agreement protocol (AP) mode. Use undo ap-mode to restore the default. Syntax ap-mode { both | multicast | off } undo ap-mode Default AP is enabled for both unicast and multicast FDB entries. Views SPBM view Predefined user roles...
  • Page 6: Area-Authentication-Mode

    Syntax area-authentication send-only undo area-authentication send-only Default ISIS-SPB authenticates incoming topology advertisement packets area authentication (area-authentication-mode) is configured. The device accepts a topology advertisement packet only if the authentication method and password in the packet match its local authentication settings. Views SPBM view Predefined user roles...
  • Page 7: B-Vlan

    Parameters md5: Specifies MD5 authentication. simple: Specifies simple authentication. cipher: Sets a password in ciphertext. cipher-string: Specifies the ciphertext form of the password, a case-sensitive string of 33 to 53 characters. plain: Sets a password in plain text. plain-string: Specifies the plaintext form of the password, a case-sensitive string of 1 to 16 characters. For security purposes, all passwords, including passwords configured in plain text, are saved in ciphertext.
  • Page 8: Bandwidth-Reference

    Parameters vlan-id: Specifies a B-VLAN ID in the range of 1 to 4094. Usage guidelines An SPBM VSI can work only after it is assigned a B-VLAN. You can assign only one B-VLAN to an SPBM VSI, but different SPBM VSIs can use the same B-VLAN. For an SPBM VSI, you must specify the same I-SID and B-VLAN across all BEBs and BCBs.
  • Page 9: Bridge-Priority

    Related commands circuit-cost • spbm cost • bridge-priority Use bridge-priority to configure the SPBM bridge priority. Use undo bridge-priority to restore the default. Syntax bridge-priority priority undo bridge-priority Default The SPBM bridge priority is 32768. Views SPBM view Predefined user roles network-admin Parameters priority: Specifies a bridge priority.
  • Page 10: Control-Address

    Predefined user roles network-admin Parameters value: Specifies a link metric value in the range of 1 to 16777215. Usage guidelines The following methods are available for you to assign a link metric value to an interface: Setting an interface-specific value in interface view. •...
  • Page 11: Display L2Vpn Minm Connection

    all-l2-is: Sets the control MAC address to 0180-C200-0015. This MAC address represents all Level-2 intermediate systems. all-pb: Sets the control MAC address to 0180-C200-002E. This MAC address represents all provider bridge intermediate systems. Usage guidelines ISIS-SPB uses a group MAC address for ISIS-SPB peer-to-peer communication. This group MAC specifies the destination MAC address for ISIS-SPB protocol frames.
  • Page 12: Display L2Vpn Minm Forwarding

    10002 9999-8988-7777 1234 FGE1/0/1 10002 9999-9088-7777 1234 FGE1/0/1 FGE1/0/2 Command output Field Description Link ID Link ID of the MAC-in-MAC connection. I-SID Backbone service instance identifier. BMAC Backbone MAC address. BVLAN Backbone VLAN. Entry source: Owner • PBB—The connection is set up by PBB. •...
  • Page 13: Display L2Vpn Vsi

    Link ID I-SID BMAC BVLAN Owner Type Interface 10001 9999-8888-7777 1234 FGE1/0/1 10001 9999-8988-7777 1234 FGE1/0/1 10001 0011-2222-3333 1234 FGE1/0/1 VSI name: 2 Link ID I-SID BMAC BVLAN Owner Type Interface 10002 9999-8888-7777 1234 FGE1/0/1 10002 9999-8988-7777 1234 FGE1/0/1 10002 9999-9088-7777 1234 FGE1/0/1...
  • Page 14 verbose: Displays detailed VSI information. If you do not specify this keyword, the command displays brief VSI information. Examples # Display detailed information about all VSIs. <Sysname> display l2vpn vsi verbose VSI Name: 1000 VSI Index : 744 VSI State : Up : 1500 Bandwidth...
  • Page 15: Display Spbm Agreement-Protocol

    Command output Field Description VSI description. This field appears only if you have configured a description for VSI Description the VSI. VSI state: • Up—The VSI is up. VSI State • Down—The VSI is down. • Administratively down—The VSI has been manually shut down with the shutdown command.
  • Page 16 Predefined user roles network-admin network-operator Parameters interface interface-type interface-number: Specifies an interface by its type and number. ect ect-number: Specifies an ECT algorithm index in the range of 1 to 16. standby slot slot-number: Specifies a subordinate device by its IRF member ID. If you do not specify a subordinate device, the command displays information for the master device.
  • Page 17: Display Spbm B-Vlan

    Field Description TxAN Local agreement number. TxDAN Local discarded agreement number. RxAN Neighbor's agreement number. RxDAN Neighbor's discarded agreement number. TxValid Validity of the local digest. RxValid Validity of the neighbor's digest. MisOrder Whether the message is out of order. TopoAgree Whether the topologies of the two sides match.
  • Page 18: Display Spbm Bridge

    Views Any view Predefined user roles network-admin network-operator Parameters vlan-id: Specifies a B-VLAN ID in the range of 1 to 4094. If you do not specify a B-VLAN ID, the command displays ECT algorithm information for all B-VLANs. standby slot slot-number: Specifies a subordinate device by its IRF member ID. If you do not specify a subordinate device, the command displays information for the master device.
  • Page 19: Display Spbm Bvlan-Info

    Syntax display spbm bridge Views Any view Predefined user roles network-admin network-operator Examples # Display SPBM bridge information. <Sysname> display spbm bridge System ID Priority SPSource ID Host name 5555.1111.1111 32768 SPB-1 Command output Field Description Priority Bridge priority. SPSource ID Shortest path source identifier.
  • Page 20: Display Spbm Bvlan-Info Statistics

    Command output Field Description Epoch Number of SPBM process reinitiations. Config B-VLAN list B-VLANs mapped to MSTI 4092 at the CLI. Driver B-VLAN list B-VLANs issued to the driver. display spbm bvlan-info statistics Use display spbm bvlan-info statistics to display SPBM B-VLAN statistics. Syntax display spbm bvlan-info statistics [ slot slot-number ] Views...
  • Page 21: Display Spbm Common Statistics

    Field Description AllocBVLANFail Number of B-VLAN allocation failures. display spbm common statistics Use display spbm common statistics to display global SPBM statistics. Syntax display spbm common statistics [ slot slot-number ] Views Any view Predefined user roles network-admin network-operator Parameters slot slot-number: Specifies an IRF member device by its member ID.
  • Page 22: Display Spbm Ect

    Field Description Number of global SPBM process reinitiations. If the timestamp of an entry EpochNumber is smaller than this value, the entry is deleted. GetBMACNumber Number of attempts to get B-MAC addresses from the driver. GetBMACFail Number of failures to get B-MAC addresses from the driver. SetIfNumber Number of SPBM enabling attempts on the interface.
  • Page 23 Inactive B-VLANs: N/A ECT-5: Algorithm: 00-80-c2-05 Mask: 0x44 Active B-VLANs: N/A Inactive B-VLANs: N/A ECT-6: Algorithm: 00-80-c2-06 Mask: 0x33 Active B-VLANs: N/A Inactive B-VLANs: N/A ECT-7: Algorithm: 00-80-c2-07 Mask: 0xcc Active B-VLANs: N/A Inactive B-VLANs: N/A ECT-8: Algorithm: 00-80-c2-08 Mask: 0xbb Active B-VLANs: N/A Inactive B-VLANs: N/A ECT-9:...
  • Page 24: Display Spbm Ect-Migration I-Sid

    Inactive B-VLANs: N/A Command output Field Description Algorithm ECT algorithm. Mask ECT algorithm mask. Active B-VLANs mapped to the ECT algorithm. Active B-VLANs are VLANs mapped to MSTI 4092. Active B-VLANs This field displays N/A if no active B-VLANs are mapped to the algorithm. Inactive B-VLANs mapped to the ECT algorithm.
  • Page 25: Display Spbm Fast-Channel Statistics

    Field Description Receive (R) bit identifies the device's receiver status in the multicast group for the I-SID: • 1—R bit set. The device is a receiver. • 0—R bit not set. The device is not a receiver. display spbm fast-channel statistics Use display spbm fast-channel statistics to display fast-channel statistics.
  • Page 26: Display Spbm Graceful-Restart Event-Log

    Field Description Multicast replication mode: Replication mode • head-end—Head-end replication. • tandem—Tandem replication. ECT algorithm ECT algorithm for the B-VLAN. Number of LSPs transmitted in the fast channel. This field is cleared when one of the following events occurs: • The reset spbm database command is executed.
  • Page 27: Display Spbm Graceful-Restart Status

    Aug 22 08:21:17 2013 -Slot=1 enter GR phase (Flush smooth). Aug 22 08:21:17 2013 -Slot=1 enter GR phase (Finish). Aug 22 08:21:17 2013 -Slot=1 GR complete. Command output Field Description Initialization ISIS-SPB Graceful Restart was initialized. LSDB synchronization Peer ISIS-SPB processes synchronized LSDBs. LSP stability The local LSDB converged.
  • Page 28 Command output Field Description Restart state of the device: • Restarting—The device is rebooting ISIS-SPB or performing an active/standby MPU switchover. In this state, the device can forward traffic because its FIB is usable. Restart status • Starting—The device is rebooting. In this state, the device cannot forward traffic because the FIB is not usable.
  • Page 29: Display Spbm Interface

    Field Description CSNP received Whether the interface received a CSNP from the neighbor device. Number of T1 timer expirations on the interface. When this counter reaches T1 expirations 10, the restarting device stops retransmitting hello messages with the RR bit set. display spbm interface Use display spbm interface to display information about SPBM-enabled interfaces.
  • Page 30: Display Spbm Lsdb

    Interface Circuit ID State Cost FGE1/0/2 1497 Hello timer : 10 Hello multiplier LSP timer : 33 LSP transmitted count : 5 # Display detailed SPBM information for FortyGigE 1/0/1. <Sysname> display spbm interface fortygige 1/0/1 verbose Interface information for SPBM ------------------------------ Interface Circuit ID...
  • Page 31 Parameters lsp-id lspid: Specifies an LSP ID in SYSID.Pseudonode ID-fragment num format. The SYSID argument represents the system ID of the LSP originating node. The Pseudonode ID argument represents the ID of the pseudonode. The fragment num argument represents the LSP fragment number. lsp-name lspname: Specifies the LSP name in Symbolic name-fragment num format.
  • Page 32 CIST root identifier : 0000-0000-0000-0000 CIST ERPC Bridge priority : 32768 SPSourceID : 100 Number of trees B-VLAN: 10 U-Bit: 1 ECT: 00-80-c2-01 SPVID: 0 0011.2200.0001.00-01 0x0000000f 0x209e 1190 System ID : 0011.2200.0001 Hostname : 0011.2200.0001.00 MT capability TLV: MT ID : 00 MT overload : 0 SPBM Service Identifier and Unicast Address sub-TLV:...
  • Page 33 Extended neighbor reachability TLV: Hostname : 0011.2200.0001.00 Cost : 10 Port number : 1 Command output Field Description LSP ID LSP ID. An asterisk (*) indicates a local LSP. Seq Num LSP sequence number. Checksum LSP checksum. Holdtime LSP lifetime (in seconds), which decreases as time elapses. Length LSP length.
  • Page 34: Display Spbm Multicast-Fdb

    Field Description I-SID and the multicast group membership flags of the LSP originating device for the I-SID. The following are the flags: • T—T bit set. The LSP originating device is a transmitter in the multicast group for I-SID the I-SID. •...
  • Page 35: Display Spbm Multicast-Fdb Count

    0011.2200.de01 9334-6900-03e8 7 FGE1/0/1 0011.2200.de01 9334-6900-0190 4 FGE1/0/2 0011.2200.de01 9334-6900-01f4 5 FGE1/0/3 Command output Field Description MAC address Multicast MAC address. Forwarding actions: • E—Forwards the frame out of the tunnel to the customer site. Flags • T—Forwards the frame to the next node in the tunnel. If this field displays both flags, the device performs both actions.
  • Page 36 Predefined user roles network-admin network-operator Parameters mac-address mac-address: Specifies an SPBM multicast address in H-H-H format. You can omit the consecutive 0s at the beginning of each segment. For example, you can enter f-e2-1 for 000f-00e2-0001. If you do not specify a multicast address, the command displays FIB entries for all multicast B-MACs.
  • Page 37: Display Spbm Multicast-Fib Count

    Field Description B-VLAN B-VLAN that contains the entry. Forwarding actions: • E—Forwards the frame out of the tunnel to the customer site. Flags • T—Forwards the frame to the next node in the tunnel. If this field displays both flags, the device performs both actions. State of issuing the entry to the driver: •...
  • Page 38: Display Spbm Multicast-Fib Statistics

    display spbm multicast-fib statistics Use display spbm multicast-fib statistics to display SPBM multicast FIB statistics. Syntax display spbm multicast-fib statistics [ slot slot-number ] Views Any view Predefined user roles network-admin network-operator Parameters slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a member device, the command displays multicast FIB statistics for each member device.
  • Page 39: Display Spbm Multicast-Pw

    Field Description AgeNumber Number of expired entries. DrvAdd Number of multicast entries added to the driver. DrvDelete Number of multicast entries deleted from the driver. DrvAddIf Number of outgoing interfaces added to the driver. DrvDeleteIf Number of outgoing interfaces deleted from the driver. DrvModifyFlag Number of times the driver modified the forwarding state.
  • Page 40: Display Spbm Non-Stop-Routing Event-Log

    count: Displays the total number of multicast PWs. If you do not specify this keyword, the command only displays multicast PW information. Usage guidelines Use this command on a BEB that uses tandem replication to verify multicast PW information. The multicast PW table is empty on the following SPBM nodes: BEBs that use head-end replication—Head-end replication does not require multicast PWs •...
  • Page 41: Display Spbm Non-Stop-Routing Status

    <Sysname> display spbm non-stop-routing event-log slot 1 SPBM log information: Aug 22 08:21:17 2013 -Slot=1 enter NSR phase (Initialization). Aug 22 08:21:17 2013 -Slot=1 enter NSR phase (Smooth). Aug 22 08:21:17 2013 -Slot=1 enter NSR phase (LSP stability). Aug 22 08:21:17 2013 -Slot=1 enter NSR phase (LSP generation). Aug 22 08:21:17 2013 -Slot=1 enter NSR phase (SPF computation).
  • Page 42: Display Spbm Peer

    Command output Field Description NSR phase: • Initialization—ISIS-SPB NSR is initialized. • Smooth—ISIS-SPB NSR smooth starts. • LSP stability—The local LSDB is converging. NSR phase • LSP generation—ISIS-SPB generates and floods LSPs. • SPF computation—ISIS-SPB performs SPF computation. • Flush smooth—ISIS-SPB smoothes kernel data. •...
  • Page 43 System ID Port Circuit ID State Holdtime 5555.1111.1111 FGE1/0/2 Peer information: Host name: spbm-2 Circuit ID: 1 Cost: 10 MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 Aux MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7...
  • Page 44 Host name: spbm-3 Circuit ID: 1 Cost: 10 MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 Aux MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 AP information: AN: 2 DAN: 0 Valid: 1 Format identifier...
  • Page 45: Command Output

    Peer information: Host name: spbm-2 Circuit ID: 1 Cost: 10 MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 Aux MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 AP information: AN: 2 DAN: 0 Valid: 1...
  • Page 46 Field Description Circuit ID Circuit ID of the link connected to the neighbor. State of the adjacency with the neighbor: • Init—The device is trying to establish an adjacency with the neighbor. • Up—An adjacency has been established, and the link is up. Traffic can be transmitted on this adjacency.
  • Page 47: Display Spbm Summary

    Field Description Validity of the advertised AP digest: Valid • 0—The digest is invalid. • 1—The digest is valid. Format identifier Digest format identifier. Format capalities Digest format options. Loop-free forwarding rules: • 1—No digest match. AP is disabled. Digests are exchanged but a match is not required.
  • Page 48 System name : spb-1 Bridge priority : 32768 SPSource ID : 200 SPSource mode : Static Agreement mode : Both MCID information: Format selector Region name : spb Revision level Configuration digest : 0x0253c1480d244e443b21e7c364d6e2a7 B-VLANs : 1-10, 100-200 Command output Field Description Area address...
  • Page 49: Display Spbm Unicast-Fdb

    display spbm unicast-fdb Use display spbm unicast-fdb to display SPBM unicast FDB entries. Syntax display spbm unicast-fdb [ b-mac mac-address | b-vlan vlan-id | system-id system-id ] Views Any view Predefined user roles network-admin network-operator Parameters b-mac mac-address: Specifies a B-MAC address in H-H-H format. You can omit the consecutive 0s at the beginning of each segment.
  • Page 50: Display Spbm Unicast-Fib

    Syntax display spbm unicast-fdb [ b-mac mac-address | b-vlan vlan-id | system-id system-id ] count Views Any view Predefined user roles network-admin network-operator Parameters b-mac mac-address: Specifies a B-MAC address in H-H-H format. You can omit the consecutive 0s at the beginning of each segment.
  • Page 51 b-mac mac-address b-vlan vlan-id: Specifies a B-MAC in a B-VLAN. If you do not specify this option, the command displays all unicast FIB entries. verbose: Displays detailed information about unicast FIB entries. If you do not specify this keyword, the command only displays brief information.
  • Page 52: Display Spbm Unicast-Fib Count

    Field Description Context Context that the driver returned when the entry was set in the driver. display spbm unicast-fib count Use display spbm unicast-fib count to display the number of SPBM unicast FIB entries. Syntax display spbm unicast-fib [ b-vlan vlan-id ] [ slot slot-number ] count Views Any view Predefined user roles...
  • Page 53: Display Spbm Unicast-Pw

    RefreshMsg DeleteMsg AddUMACNumber DeleteUMACNumber : 0 DeleteNotFound : 0 AgeNumber DrvAdd DrvDelete DrvDelRefresh SPBM unicast FIB error statistics: UMACMsgError RefreshMsgFail DeleteMsgFail AddUMACFail DrvOtherFail DrvDeleteFail DrvNoResource SynMsgFail AllocEntryFail : 0 AllocReDrvMsgFail: 0 Command output Field Description RefreshMsg Number of messages received for refreshing unicast FIB entries. DeleteMsg Number of messages received for deleting unicast FIB entries.
  • Page 54: Display Spbm Unicast-Tree

    Views Any view Predefined user roles network-admin network-operator Parameters i-sid i-sid: Specifies an I-SID in the range of 255 to 16777215. If you do not specify an I-SID, the command displays unicast PW information for all I-SIDs. count: Displays the total number of unicast PWs. If you do not specify this keyword, the command displays unicast PW information.
  • Page 55: Ect

    network-operator Examples # Display SPBM unicast tree information. <Sysname> display spbm unicast-tree SPF tree information for SPBM ------------------------------ Flags: S-Node is on SPF tree D-Node or Link is to be deleted O-Node is overload I-Node is invalid T-Node is on tent list P-Neighbor is parent node C-Neighbor is child node L-Link is on changelist...
  • Page 56: Encapsulation

    Use undo ect to remove ECT algorithm and B-VLAN mappings. Syntax ect ect-index b-vlan vlan-id-list undo ect ect-index b-vlan [ vlan-id-list ] Default All B-VLANs are mapped to ECT 1. Views SPBM view Predefined user roles network-admin Parameters ect-index: Specifies an ECT algorithm index in the range of 1 to 16. vlan-id-list: Specifies a space-separated list of up to 10 B-VLAN items.
  • Page 57 undo encapsulation Default An Ethernet service instance does not contain match criteria. Views Ethernet service instance view Predefined user roles network-admin Parameters default: Matches all traffic that does not match any other Ethernet service instance on the interface. On an interface, you can configure this criterion only in one Ethernet service instance. tagged: Matches all frames that have an 802.1Q VLAN tag.
  • Page 58: Flash-Flood

    [Sysname-FortyGigE1/0/1] service-instance 1 [Sysname-FortyGigE1/0/1-srv1] encapsulation s-vid 111 flash-flood Use flash-flood to enable fast flooding of LSPs. Use undo flash-flood to restore the default. Syntax flash-flood [ flood-count flooding-count | max-timer-interval flooding-interval ] * undo flash-flood Default Fast flooding of LSPs is disabled. Views SPBM view Predefined user roles...
  • Page 59: Graceful-Restart Suppress-Sa

    Default GR is disabled for SPBM. Views SPBM view Predefined user roles network-admin Usage guidelines Enable Graceful Restart before you re-enable SPBM or perform an active/standby switchover. Graceful Restart ensures nonstop forwarding while ISIS-SPB processes are re-establishing their adjacency. Examples # Enable Graceful Restart for SPBM.
  • Page 60: Graceful-Restart T2

    graceful-restart t2 Use graceful-restart t2 to configure the T2 timer for ISIS-SPB GR. Use undo graceful-restart t2 to restore the default. Syntax graceful-restart t2 t2-value undo graceful-restart t2 Default The T2 timer is 300 seconds. Views SPBM view Predefined user roles network-admin Parameters t2-value: Specifies the T2 timer in the range of 30 to 1800 seconds.
  • Page 61: L2Vpn Enable

    Parameters is-name: Assigns a hostname to the device, a string of 1 to 64 characters. Usage guidelines ISIS-SPB uses a 6-byte system ID to represent a node in the network. This representation method is difficult for administrators to identify devices when they examine ISIS-SPB adjacencies, FDB entries, and LSDB entries.
  • Page 62: Multicast Replicate-Mode

    undo log-peer-change Default ISIS-SPB adjacency changes are output to the configuration terminal. Views SPBM view Predefined user roles network-admin Usage guidelines This command enables SPBM to output adjacency change events to the configuration terminal. To display adjacency change messages on the terminal screen, make sure the terminal logging and terminal monitor commands are configured.
  • Page 63: Multicast-Bvlan Enable

    Tandem replication—Replicates frames only at the node where the shortest path tree forks. This • method is suitable for SPBM VSIs that have dense multicast traffic. It requires BCBs to maintain multicast FDB entries. Head-end replication is suitable for service instances that have sparse multicast traffic. Tandem replication is suitable for service instances that have dense multicast traffic.
  • Page 64: Non-Stop-Routing

    <Sysname> system-view [Sysname] spbm [Sysname-spbm] multicast-bvlan enable non-stop-routing Use non-stop-routing to enable NSR for SPBM. Use undo non-stop-routing to restore the default. Syntax non-stop-routing undo non-stop-routing Default NSR is disabled for SPBM. Views SPBM view Predefined user roles network-admin Usage guidelines NSR and Graceful Restart are mutually exclusive.
  • Page 65: Reset Spbm Database

    reset spbm database Use reset spbm database to clear operating data from the SPBM databases, including the LSDB, FDBs, FIBs, and PW tables. Syntax reset spbm database [ graceful-restart ] Views User view Predefined user roles network-admin Parameters graceful-restart: Enables SPBM database restoration through the Graceful Restart feature. If you do not specify this keyword, you must use other methods to restore SPBM data after the database is cleared.
  • Page 66: Reset Spbm Non-Stop-Routing Event-Log

    Views User view Predefined user roles network-admin Parameters slot slot-number: Specifies an IRF member device by its member ID. Examples # Clear SPBM multicast FIB statistics. <Sysname> reset spbm multicast-fib statistics slot 1 reset spbm non-stop-routing event-log Use reset spbm non-stop-routing event-log to clear the SPBM NSR log. Syntax reset spbm non-stop-routing event-log slot slot-number Views...
  • Page 67: Service-Instance

    Examples # Clear SPBM unicast FIB statistics. <Sysname> reset spbm unicast-fib statistics slot 1 service-instance Use service-instance to create a service instance on a Layer 2 Ethernet interface or enter service instance view. Use undo service-instance to delete a service instance. Syntax service-instance instance-id undo service-instance instance-id...
  • Page 68: Snmp-Agent Trap Enable Spbm

    Parameters on-startup: Sets the overload bit when the system starts up. start-from-nbr system-id [ timeout1 [ nbr-timeout ] ]: Sets the timers for controlling the overload bit state during the process of adjacency establishment. The nbr-timeout timer starts when the device starts up. If the device fails to establish an adjacency with the neighbor identified by system-id before the timer expires, the overload bit is cleared.
  • Page 69: Spb I-Sid

    Parameters b-mac-conflict: Specifies the B-MAC conflict notification. This notification is generated when a remote B-MAC conflicts with a local B-MAC. spsource-conflict: Specifies the SPSource ID conflict notification. This notification is generated when a remote SPSource ID conflict with the local SPSource ID. Usage guidelines The command enables both B-MAC conflict and SPSource ID conflict notifications if you execute the command without any keywords.
  • Page 70: Spbm

    <Sysname> system-view [Sysname] vsi vpn1 [Sysname-vsi-vpn1] spb i-sid 256 [Sysname-vsi-vpn1-256] spbm Use spbm to enable SPBM globally and enter SPBM view. Use undo spbm to restore the default. Syntax spbm undo spbm Default SPBM is disabled globally. Views System view Predefined user roles network-admin Usage guidelines...
  • Page 71: Spbm Authentication-Mode

    Default ISIS-SPB authenticates incoming ISIS-SPB hello packets on an interface if adjacency authentication (spbm authentication-mode) is enabled on the interface. Views Layer 2 Ethernet interface view, Layer 2 aggregate interface view Predefined user roles network-admin Usage guidelines Before you change adjacency authentication settings on a link, configure this command to prevent temporary authentication setting mismatch from causing loss of adjacencies.
  • Page 72: Spbm Cost

    cipher-string: Specifies the ciphertext form of the password, a case-sensitive string of 33 to 53 characters. plain: Sets a password in plain text plain-string: Specifies the plaintext form of the password, a case-sensitive string of 1 to 16 characters. For security purposes, all passwords, including passwords configured in plain text, are saved in cipher text.
  • Page 73: Spbm Enable

    Setting an interface-specific value in interface view. • • Setting a global value in SPBM view. This global value applies to all SPBM-enabled interfaces. Setting a bandwidth reference for the system to calculate a value automatically for the interface. • The system chooses a link metric value for an interface in order of interface-specific value, global value, and autocalculated value.
  • Page 74: Spbm Timer Holding-Multiplier

    undo spbm timer hello Default The hello interval is 10 seconds. Views Layer 2 Ethernet interface view, Layer 2 aggregate interface view Predefined user roles network-admin Parameters seconds: Specifies an interval in the range of 3 to 255 seconds. Usage guidelines ISIS-SPB sends hellos over links to establish and maintain adjacencies between SPBM nodes.
  • Page 75: Spbm Timer Lsp

    Usage guidelines Adjacency hold time specifies the amount of time for one SPBM node to retain the adjacency with another. This timer determines how quick it takes for an SPBM node to detect a failed link. The adjacency hold time equals the hello interval multiplied by the hello multiplier. An SPBM node sends its adjacency hold time in hello packets to update the adjacencies with its neighbor.
  • Page 76: Spsource

    Examples # Set the minimum LSP transmit interval to 500 milliseconds on FortyGigE 1/0/1. <Sysname> system-view [Sysname] interface fortygige 1/0/1 [Sysname-FortyGigE1/0/1] spbm timer lsp 500 spsource Use spsource to configure an SPSource ID. Use undo spsource to restore the default. Syntax spsource spsource-id undo spsource...
  • Page 77: Timer Lsp-Max-Age

    The minimum interval is 10 milliseconds. The base number for the incremental interval is 10 milliseconds. Views SPBM view Predefined user roles network-admin Parameters maximum-interval: Specifies the maximum LSP generation interval in the range of 1 to 120 seconds. minimum-interval: Specifies the minimum LSP generation interval in the range of 10 to 60000 milliseconds.
  • Page 78: Timer Lsp-Refresh

    Default The maximum LSP lifetime is 1200 seconds. Views SPBM view Predefined user roles network-admin Parameters seconds: Specifies the maximum LSP lifetime in the range of 1 to 65535 seconds. Usage guidelines This command specifies the maximum amount of time for an LSP generated by the device to be retained in an LSDB.
  • Page 79: Timer Spf

    Parameters seconds: Specifies the LSP refresh interval in the range of 1 to 65534 seconds. Usage guidelines To prevent LSPs from age-out and synchronize LSDBs, ISIS-SPB performs periodic LSP update. The LSP refresh interval sets the interval at which ISIS-SPB regularly regenerates an LSP, regardless of whether any change has occurred to the LSP.
  • Page 80: Vsi

    Usage guidelines The SPF calculation timer sets the delay between consecutive SPF calculations. You can increase the timer for ISIS-SPB to react quickly to topology changes, and decrease the timer to protect the CPU from frequent SPF calculations. The SPF timer is an exponential generation timer. With this timer, ISIS-SPB quickly responds to the first events that trigger SPF calculation and then slows down to protect the CPU from frequent SPF calculations.
  • Page 81: Xconnect Vsi

    [Sysname] vsi vpls1 [Sysname-vsi-vpls1] xconnect vsi Use xconnect vsi to bind a Layer 3 interface or an Ethernet service instance to a VSI. Use undo xconnect vsi to remove the binding. Syntax xconnect vsi vsi-name [ access-mode { ethernet | vlan } ] undo xconnect vsi Default An Ethernet service instance is not bound to any VSI.
  • Page 82: Related Commands

    [Sysname] interface fortygige 1/0/1 [Sysname-FortyGigE1/0/1] service-instance 200 [Sysname-FortyGigE1/0/1-srv200] encapsulation s-vid 200 [Sysname-FortyGigE1/0/1-srv200] xconnect vsi vpn1 Related commands encapsulation • •...
  • Page 83: Support And Other Resources

    Related information Documents To find related documents, browse to the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For related documentation, navigate to the Networking section, and select a networking category. •...
  • Page 84: Conventions

    Conventions This section describes the conventions used in this documentation set. Command conventions Convention Description Boldface Bold text represents commands and keywords that you enter literally as shown. Italic Italic text represents arguments that you replace with actual values. Square brackets enclose syntax choices (keywords or arguments) that are optional. Braces enclose a set of required syntax choices separated by vertical bars, from which { x | y | ...
  • Page 85 Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features.
  • Page 86: Index

    Index A B C D E F G I L M N R S T V X display spbm peer,38 display spbm summary,43 ap-mode,1 display spbm unicast-fdb,45 area-authentication send-only,1 display spbm unicast-fdb count,45 area-authentication-mode,2 display spbm unicast-fib,46 display spbm unicast-fib count,48 display spbm unicast-fib statistics,48...
  • Page 87 reset spbm unicast-fib statistics,62 spbm timer lsp,71 spsource,72 service-instance,63 set-overload,63 timer lsp-generation,72 snmp-agent trap enable spbm,64 timer lsp-max-age,73 i-sid,65 timer lsp-refresh,74 spbm,66 timer spf,75 spbm authentication send-only,66 spbm authentication-mode,67 vsi,76 spbm cost,68 spbm enable,69 spbm timer hello,69 xconnect vsi,77 spbm timer holding-multiplier,70...

Table of Contents