Autotest In Far End Source Mode - Fluke DTX-CLT CertiFiber User Manual

Optical loss test set
Hide thumbs Also See for DTX-CLT CertiFiber:
Table of Contents

Advertisement

DTX-CLT CertiFiber Optical Loss Test Set
Users Manual

Autotest in Far End Source Mode

Use Far End Source mode to measure loss at one
wavelength on individual fibers.
A
Tester and smart remote with fiber modules and
connector adapters installed (match connector adapters
to the connectors in the link)
B
Two AC adapters with line cords (optional)
C
Test reference cord. Match the fiber to be tested. SC
connector at one end. Match the link connectors at the
other end.
Figure 20. Equipment for Testing in Far End Source Mode (1 Jumper Method)
44
Far End Source mode requires a stand-alone optical source.
Figure 20 shows the equipment required for testing fiber
in Far End Source mode.
D
Test reference cord. Match the fiber and connectors in
the link.
E
Singlemode adapter of the appropriate type.
F
Mandrel. Recommended when testing multimode
fiber with a DTX-MFM2 module. See page 18.
G
Fiber cleaning supplies
H
A microscope for inspecting fiber connectors (the
FT500 FiberInspector Mini Video Microscope is shown)
gfd16f.eps