Further details regarding the individual steps
Matching the control unit to the heating system
The control unit must be adjusted subject
to the system equipment level.
■ To do this, select the relevant system
scheme (see the following diagrams).
■ Set the codes in conjunction with the
accessories fitted:
Installation and service instruc-
tions for accessories
System version 1
One heating circuit without mixer A1 (with/without DHW heating)
1
4
5
ID: 4605145_1001_01
1 Vitodens 200-W
2 Outside temperature sensor (only
for weather-compensated control
units)
3 Vitotrol 100 (only for constant tem-
perature control units)
Commissioning, inspection, maintenance
Note
Various system components are recog-
nised automatically by the control unit
and the relevant codes are adjusted
automatically.
For coding steps, see page 60.
3
6
2
4 DHW cylinder
5 Cylinder temperature sensor
6 Heating circuit without mixer A1
(cont.)
(heating circuit 1)
49