Fault codes
(cont.)
Dis-
Const.
played
fault
code
28
X
30
X
38
X
40
44
48
4C
Weath.-
System char-
comp.
acteristics
X
Regulates with-
out flow tem-
perature sen-
sor (low loss
header)
X
Burner blocked Short circuit,
X
Burner blocked Lead break,
X
Mixer closes
X
Mixer closes
X
Mixer closes
X
Mixer closes
Troubleshooting
Cause
Measures
Lead break,
Check low loss
flow tempera-
header sensor (see
ture sensor
page 130)
If no low loss head-
er sensor is con-
nected, set code
52:0.
Check the boiler
boiler water
water temperature
temperature
sensor (see
sensor
page 130)
Check the boiler
boiler water
water temperature
temperature
sensor (see
sensor
page 130)
Short circuit,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 138)
heating circuit
2 (with mixer)
Short circuit,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 138)
heating circuit
3 (with mixer)
Lead break,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 138)
heating circuit
2 (with mixer)
Lead break,
Check flow temper-
flow tempera-
ature sensor (see
ture sensor,
page 138)
heating circuit
3 (with mixer)
113