Removal Of Drain Pan / Indoor Heat Exchanger Assy - Daikin FVXG25K2V1B Service Manual

Pair, floor standing type k-series, heat pump, indoor/outdoor units
Hide thumbs Also See for FVXG25K2V1B:
Table of Contents

Advertisement

Indoor Unit
1.9

Removal of Drain Pan / Indoor Heat Exchanger ASSY

Procedure
Step
1. Remove the drain pan.
1
Unfasten the hook and
remove the drip proof
sheet.
Remove the screw.
2
Remove the piping
3
fixture.
157
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hook
Drip proof
sheet
(R15103)
(R15104)
Piping fixture
(R15105)
SiBE061121
Points
The drip proof sheet is
transparent.