Daikin FVXG25K2V1B Service Manual page 171

Pair, floor standing type k-series, heat pump, indoor/outdoor units
Hide thumbs Also See for FVXG25K2V1B:
Table of Contents

Advertisement

SiBE061121
Step
11
Disconnect the drain
hose.
12
Remove the drain pan.
2. Remove the indoor heat
exchanger ASSY.
Remove the indoor
1
electronic expansion
valve coil.
2
Unfasten the hook and
disconnect the relay
connector for the indoor
heat exchanger
thermistor.
Removal Procedure
Procedure
Drain hose
Drain pan
Indoor electronic expansion valve coil
Hook
Be careful not to wet the
floor with drain.
(R15315)
(R15142)
There is a hook inside the
indoor electronic expansion
valve coil. Do not deform the
hook.
(R15113)
(R15316)
Indoor Unit
Points
160