SiBE061121
Step
3
Remove the nut of the
outdoor fan.
Remove the lower 2
4
screws from the fan
motor first.
Then, remove the 2
5
upper screws.
Removal Procedure
Procedure
Outdoor fan
Outdoor Unit - RXG50K2V1B
Nut size: M6
(R5262)
When reassembling, align
with D-cut section of the
motor shaft.
(R5263)
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor, the center of
gravity of which is toward the
front, may tilt down or fall,
getting you injured.
Fan motor
(R5264)
Points
10 mm
(R12236)
mark of the outdoor fan
202