Daikin FVXG25K2V1B Service Manual page 191

Pair, floor standing type k-series, heat pump, indoor/outdoor units
Hide thumbs Also See for FVXG25K2V1B:
Table of Contents

Advertisement

SiBE061121
Step
4
Pull out the forced
cooling operation
switch PCB.
Disconnect the
connector [S110] to
remove the forced
cooling operation
switch PCB.
Disconnect the
5
selective connector for
standby electricity
saving and pull out the
relay connector.
Cut the clamp.
6
Removal Procedure
Procedure
Forced cooling operation switch PCB
Outdoor Unit - RXG25/35K2V1B
Be careful of a sharp
protrusion at the back of the
forced cooling operation
switch PCB.
[S110]
(R15383)
Relay
connector
Selective connector
(R13507)
(R11858)
Points
180