Omron DST1-ID12SL-1 Operation Manual page 99

Dst1 series safety i/o terminals
Hide thumbs Also See for DST1-ID12SL-1:
Table of Contents

Advertisement

Remote I/O Allocations
Network Configurator
setting
Safety input assembly 1
Safety input assembly 2
Safety input assembly 3
Safety input assembly 4
Safety input assembly 5
Standard output assembly
Safety output assembly 1
Safety output assembly 2
General status assembly
Output monitor/test out-
put status with general
status assembly
DST1-XD0808SL-1
The following I/O data can be selected from the Network Configurator.
203
Input 1
330
Input 1
331
Input 2
332
Input 3
333
Input 3
21
Output 1
233
Output 1
350
Output 1
300
Input 1
342
Input 2
The default values for the I/O assembly data are as follows:
Safety connections:
Default (Assembly instance number)
IN
Safety input assembly 1 (Instance No. 204)
OUT
Safety output assembly 1 (Instance No. 352)
Standard connection: The default values for each type of connection are
given below.
Connection
Poll
IN
OUT
Bit strobe
IN
OUT
COS
IN
OUT
Cyclic
IN
OUT
The following I/O data can be selected from the Network Configurator.
Inputs
Default (Assembly instance number)
Safety input assembly 3 (No. 3A1)
None
Safety input assembly 3 (No. 3A1)
None
Safety input assembly 3 (No. 3A1)
None
Safety input assembly 3 (No. 3A1)
None
Section 3-2
Outputs
75