Error Code (SSB2)
0xaf22
0xaf24
0xaf25
0xaf26
0xaf29
0xaf2a
0xaf2b
0xaf2c
0xaf2e
0xaf2f
0x0b2b

Errors when operating RAID Manager (Data Retention, SSB1:2E31/B9BF/B9BD)

Error Code (SSB2)
9100
B9BD
B9C2
B9C4
210
Troubleshooting
Error Contents
The operation was rejected because the
specified volume is placed online with the OS
which does not support EAV (Extended Address
Volume).
The operation was rejected because the total
THP V-VOL capacity exceeded the pool
reservation rate after the capacity was
increased.
The operation to increase capacity cannot be
performed on the specified THP V-VOL.
The operation was rejected because of lack of
cache management devices due to increased
capacity.
Because the specified volume was not a THP
V-VOL, the operation was rejected.
Because the specified capacities are invalid or
exceeded the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window, the operation was rejected.
Because the specified volume operation was not
finished, the operation was rejected.
Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.
Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.
Because the configuration of journal volumes is
being changed, the specified THP V-VOL
capacity cannot be expanded.
Because the raidcom extend ldev
command was executed with specifying the
-cylinder option to the THP V-VOL for the
open system, the operation was rejected.
Description
The command cannot be executed because user authentication is not performed.
The setting failed because the specified volume does not exist.
The specified volume is a command device.
The command was rejected due to one of the following reasons:
The specified volume is a virtual volume.
The specified volume is a pool volume.
The specified volume is an secondary volume of Continuous Access Journal.
The specified volume is a journal volume.
Solutions
Increase the THP V-VOL capacity after the
specified volume is placed online with the OS
which supports EAV.
Specify a capacity so that the pool reservation
rate will not be exceeded.
Check the emulation type of the specified THP
V-VOL.
Specify a capacity so that the maximum number
of cache management devices will not be
exceeded.
Makes sure that the volume is a THP V-VOL.
To increase capacity, specify the correct
capacity that does not exceed the value
immediately below LDEV Capacity in the Expand
Virtual Volumes window. See the conditions for
increasing THP V-VOL capacity in
for increasing THP V-VOL capacity" (page
Re-execute the operation after a brief interval.
Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.
Wait until formatting of the specified volume is
finished, or see
"Using Thin Provisioning or
Smart Tiers with other HP XP7 Storage products"
(page 68)
and confirm whether the THP V-VOL
is used with software in which that the THP
V-VOL capacity cannot be increased.
Re-execute the operation after the journal volume
configuration is changed.
Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.
"Requirements