Item
Capacity
Used Capacity
Number of Paths
CLPR
Tiering Policy
New Page Assignment Tier
Tier Relocation
Relocation Priority
Pool Management Task
310
Thin Provisioning and Smart Tiers GUI reference
Description
Displays information about the V-VOL capacity.
Total: Displays the V-VOL capacity.
Used: Displays the V-VOL used capacity.
The displayed value on Total might be larger than the displayed value on
Used due to following reasons:
Used displays the used V-VOL capacity which is rounded up on each
page.
If the emulation type is 3390-A, the used capacity of V-VOL includes the
capacity of control cylinders (7 Cyl is required per 1,1 13 Cyl).
Used(%): Displays the V-VOL usage level.
Displays information about the used capacity of V-VOL
Tier1: Displays the used capacity of tier 1.
A hyphen (-) is displayed if the logical volume is a not a V-VOL of Smart Tiers
or Smart Tiers Z.
Tier2: Displays the used capacity of tier 2.
A hyphen (-) is displayed if tier 2 does not exist or if the logical volume is a
not a V-VOL of Smart Tiers or Smart Tiers Z.
Tier3: Displays the used capacity of tier 3.
A hyphen (-) is displayed if tier 3 does not exist or if the logical volume is a
not a V-VOL of Smart Tiers or Smart Tiers Z.
Displays the number of alternate paths. A hyphen(-) is displayed for the Thin
Provisioning Z or Smart Tiers Z V-VOL.
Displays the CLPR ID.
Displays the tiering policy name and ID.
All(0): The policy of which all tiers in the pool are used.
Level1(1) - Level5(5): One of the policy from Level1 to Level5 is set to V-VOL.
Level6(6) - Level31(31): The tiering policy of the user definition is set to V-VOL
Hyphen (-): V-VOL is not the Smart Tiers or Smart Tiers Z V-VOL.
Displays the new page assignment tier.
High: High is set to V-VOL.
Middle: Middle is set to V-VOL.
Low: Low is set to V-VOL.
Hyphen (-): V-VOL is not the Smart Tiers or Smart Tiers Z V-VOL.
Displays whether tier relocation is set to enabled or disabled. If the Smart Tiers
or Smart Tiers Z V-VOL is not used, a hyphen (-) is displayed.
Displays the relocation priority.
Prioritized: The priority is set to V-VOL.
Blank: The priority is not set to V-VOL.
Hyphen (-): V-VOL is not the Smart Tiers or Smart Tiers Z V-VOL or the tier
relocation function is disabled.
Displays the pool management task being performed to the pool.
Waiting for Rebalance: The rebalance process is being waited.
Rebalancing: The rebalance process is being performed.
Waiting for Relocation: The tier relocation process is being waited.
Relocating: The tier relocation process is being performed.