2.2

Monitor Unit

For the wiring of the monitor unit, see the operator's manual supplied with the monitor
unit.
Mounting consideration
(Standard type)
• Connect the ECDIS main monitor to the DVI1 and COM1 ports.
• For the sub ECDIS monitor, connect it to the DVI2 and COM2 port.
(Conning type)
• ECDIS main monitor: DVI1 and COM1 ports, conning monitor: DVI3 port and COM2
ports
• When an ECDIS sub monitor is added to the above connection, connect it to the
DVI2 port (the brilliance adjustment is not available).
(Notice for HD26T21-MMD-MA4-FAGA)
• For the monitor unit HD26T21-MMD-MA4-FAGA, it is required to calibrate monitor
color ([Monitor Color Calibration]) on the [Common Installation Settings] menu. For
how to calibrate monitor color, see the instruction manual (E42-01204). Also, use
the supplied cable assy. (type: DSUB9P-X2-A-L5M/10M) to connect with the pro-
cessor unit.
(VDR connection)
To connect a VDR, it is necessary to output data in analog format. See the installation
manuals for VDR to prepare the cables (BNCX5-DSUB15-Lxxx and 1.5C2V-3C2V-T)
to use.
• When connecting a VDR to the DVI3 port:
Use the optional DVI-BNCX5-L2000 cable to output RGB signal from the DVI-I. Ad-
justment of the output picture is necessary.
• When connecting a VDR to the DVI2 port:
Use a DVI/RGB converter (maker: IMAGENICS, type: DVI-12A, local supply) to
convert DVI output from DVI2 port to RGB.