Furuno FMD-3200 Installation Manual page 56

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

2. WIRING
2.5.2
Trackball control unit (RCU-026)
1. Unfasten four binding screws (M3x8) from the bottom of the control unit, and a pan
head screw (M3x8) and flat washer from the back of the control unit to remove the
cover.
Note: Be careful not to add stress to the cables connected to the control unit board
when removing the cover.
Control unit cover
2. Remove the cable clamp from the control unit, then disconnect the control unit ca-
ble from the J1 connector.
J1 connector
3. Pull out the control unit cable from the cover.
4. Pass the optional cable assy (6TPSH-XH12X2-LxxSP2) through the cable hole on
the cover.
2-36
Binding screw
Cable clamp
Disconnect this connector.
Binding screw (M3x8)
Pan head screw
and flat washer
Control unit
cable
Cable assy
(6TPSH-XH12X2-LxxSP2)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmd-3200-bbFmd-3300