How to set input specification (J4 to J9)
For connectors J4 to J7, the connections are different depending on the input specifi-
cations as shown below.
Pin
Signal
In/Out
#
name
1
TD1-A
Out
2
TD1-B
Out
3
RD1-A
In
4
RD1-B
In
5
ISOGND1
6
RD1-H
In
7
RD1-C
In
*: Set the jumpers J20/J21 to Modbus.
Pin
Signal
In/Out
#
name
1
TD2-A
Out
2
TD2-B
Out
3
RD2-A
In
4
RD2-B
In
5
ISOGND2
6
RD2-H
In
7
RD2-C
In
*: Set the jumpers J20/J21 to Modbus.
Connector J4
Description
Serial CH1, out-
put IEC61162-1/
2/modbus
Serial CH1, out-
put IEC61162-1/
2/modbus
Serial CH1, input
IEC61162-2/
modbus
Serial CH1, input
IEC61162-2/
modbus
-
Isolation, GND
(CH1)
Serial CH1, input
IEC61162-1
Serial CH1, input
IEC61162-1
Connector J5
Description
Serial CH2, out-
put IEC61162-1/
2/modbus
Serial CH2, out-
put IEC61162-1/
2/modbus
Serial CH2, input
IEC61162-2/
modbus
Serial CH2, input
IEC61162-2/
modbus
-
Isolation, GND
(CH2)
Serial CH2, input
IEC61162-1
Serial CH2, input
IEC61162-1
IEC61162-2
IEC61162-1
TTYCS(LA)-4
TTYCS(LA)-4
No connection No connection
No connection TTYCS(LA)-4
IEC61162-2
IEC61162-1
TTYCS(LA)-4
TTYCS(LA)-4
No connection No connection
No connection TTYCS(LA)-4
2. WIRING
Modbus*
TTYCS(LA)-4
Modbus*
TTYCS(LA)-4