Assigning Keypad Zones; Communicator - Dialing - DSC pc1565 Installation Manual

Hide thumbs Also See for pc1565:
Table of Contents

Advertisement

)RUFH $UP (QDEOH ± This attribute determines whether
or not the system can be armed while a zone is violated.
At the end of the exit delay, if this type of zone is violated,
it will be ignored by the panel. Once the zone is secured,
it will be monitored by the system. This zone attribute, for
example, will allow the user to arm the system with the
garage door open. Later, when the door is closed, it will
be armed along with the rest of the system. Do not pro-
gram this attribute for 24Hr zones.
6ZLQJHU 6KXWGRZQ (QDEOH ± This attribute determines
whether or not the panel will shut down the communica-
tor and bell for a zone once its swinger limit has been
reached (see section 5.19 "Swinger Shutdown" on page
23)
7UDQVPLVVLRQ 'HOD\ (QDEOH ± This attribute determines
whether or not the panel will delay communicating the
alarm reporting code for the programmed Transmission
Delay Period (see section 5.15 "Transmission Delay" on
page 22).
:LUHOHVV =RQH ± This attribute determines which zones
are to have wireless devices. This allows the panel to
generate a low battery trouble and zone supervisories for
the wireless zones.
127( $Q\ ]RQH ZLWK WKH ZLUHOHVV DWWULEXWH HQDEOHG ZLOO QRW
FDXVH DQ DODUP IRU D IDXOW FRQGLWLRQ ZKHQ DUPHG RU DQ\ WLPH
IRU KRXU ]RQHV 
Zone Attributes . . . . . . . . . . . Sections [101] - [108]: [1] - [8]
5.4

Assigning Keypad Zones

"Z" keypads have zone inputs to which devices—such as
door contacts—can be connected. (See section 2.11 "Keypad
Zones" on page 6 for wiring information.)
Once the keypad zones are installed, assign the zone in pro-
gramming section [020] .H\SDG =RQH $VVLJQPHQWV.
Enter the 2 digit zone designated for each keypad (address)
from 01-08.
Keypad Zone Assignments . . . . . . . . . . . . . . . . . . . . . . [020]
5.5
Communicator – Dialing
If the &RPPXQLFDWRU 'LVDEOH option is selected, the panel
will not attempt to call central station. If communication is
enabled, the panel will attempt to call central station when an
event with a valid reporting code occurs (See section 5.8
"Communicator – Reporting Codes" on page 16).
The &RPPXQLFDWRU &DOO 'LUHFWLRQ options are used to select
which telephone number the panel will dial when an event
occurs.
If the '70) 'LDOLQJ option is enabled, the panel will dial using
DTMF (touch tone). If the 6ZLWFK WR 3XOVH 'LDO option is
enabled, the panel will switch to pulse dialing on the fifth
attempt to call the central station. When this option is dis-
abled, the panel will always dial using DTMF. If '70) 'LDOLQJ
is disabled, the panel will always pulse dial.
When the )RUFH 'LDOLQJ option is enabled, the panel will dial
out regardless of the presence of dial tone. Each dialing
attempt will follow this pattern:
a)
the panel pick up the telephone line and search for dial
tone for 5 seconds
b)
if no dial tone is found, the panel will hang up and wait for
20 seconds
P r o g r a m
D e s c r i p t i o n s :
c)
the panel will pick up the telephone line again and search
for a dial tone for 5 seconds
d)
the panel will then dial regardless of the presence of dial
tone
If there is no initial handshake recognized within 40 seconds
the panel will then hang up the line.
If the )RUFH 'LDOLQJ option is disabled, each attempt will still
follow the above pattern, except that the panel will not dial in
step d if no dial tone is detected.
The 'HOD\ %HWZHHQ 'LDOLQJ $WWHPSWV timer adds a delay
before the next call is dialed.
If the $QWL-DP )HDWXUH is enabled, each dialing attempt will
work as follows: if there is no dial tone present on the initial
dial tone search, the panel will hang up the phone for 90ms,
and then perform another dial tone search. If no dial tone is
detected, the panel will hang up for 20 seconds, then perform
another five second dial tone search. The panel will then force
dial if force dialing is enabled. The whole sequence counts as
one dialing attempt.
0D[LPXP 'LDOLQJ $WWHPSWV determines the maximum num-
ber of attempts the panel will make to send a signal to the
central station before indicating a Failure to Communicate
(FTC) trouble condition. The maximum number of dialing
attempts that can be programmed is 15.
The UG 7HOHSKRQH 1XPEHU can be used to back up the 1st
in the event of an FTC. (see section 5.7 "Communicator – Tele-
phone Numbers" on page 16). If a later communication
attempt is successful, the FTC reporting code(s) programmed
in section [351] will be transmitted along with the unreported
events from an earlier unsuccessful communication.
When %HOO RQ )7& ZKHQ $UPHG is enabled in programming
section [702], option [8], an FTC during the armed period will
sound an Audible Alarm for the length of Bell time-out or until
the system is disarmed. If )7& 7URXEOH 2QO\ ZKHQ $UPHG is
enabled, only the keypad buzzer will sound trouble beeps
every 10 seconds until a key is pressed.
3RVW 'LDO :DLW IRU +DQGVKDNH determines the amount of time
the panel will wait for a valid handshake from the receiver. If
the panel does not hear the handshake it will consider the call
a failed attempt, hang up and try again.
The 3XOVH 'LDOLQJ 0DNH%UHDN 5DWLR option can change the
Make/Break ratio to 33/67 from the North American ratio of 40/
60.
With ,' 7RQH (QDEOHG the panel will pulse a tone on the tele-
phone line to indicate that the panel is on the line.
The +]+] option selects the frequency of the ID
tone that is pulsed on the line.
127( &RQWDFW \RXU ORFDO WHOHSKRQH FRPSDQ\ WR FRQILUP
ZKLFK VHWWLQJV VKRXOG EH XVHG
Maximum Dialing Attempts . . . . . . . . . . . . . . . . Section [160]
Post Dial Wait for Handshake . . . . . . . . . . . . . . Section [161]
Communicator Call Direction Options . . Section [361]-[368]
DTMF or Pulse Dialing . . . . . . . . . . . . . . . . Section [380]: [3]
Switch to Pulse Dialing on Fifth Attempt . . . Section [380]: [4]
Communicator Enable/Disable . . . . . . . . . . Section [380]: [1]
Anti-Jam Feature. . . . . . . . . . . . . . . . . . . . . Section [701]: [8]
Pulse Dialing Make/Break Ratio . . . . . . . . . Section [702]: [1]
Force Dialing. . . . . . . . . . . . . . . . . . . . . . . . Section [702]: [2]
ID Tone Enabled . . . . . . . . . . . . . . . . . . . . . Section [702]: [5]
2100Hz/1300Hz . . . . . . . . . . . . . . . . . . . . . Section [702]: [6]
Bell on FTC/Trouble Only. . . . . . . . . . . . . . . Section [702]: [8]
Delay Between Dialing Attempts . . . . . . . . . . . Section [703]
5 . 4
A s s i g n i n g
K e y p a d
Z o n e s