>@ .H\SDG %X]]HU )ROORZHU 0RGH
The PGM will activate when any of the following events occur
and will remain active for as long as the keypad buzzer is
active:
Door Chime
Auto-Arm Prealert
24 Hour Supervisory Buzzer Zone
>@ &RXUWHV\ 3XOVH
Upon arming, the PGM output will activate for the duration of
the exit delay plus an additional two minutes. Upon disarming,
the PGM output will activate for the duration of the entry delay
plus an additional two minutes.
>@ 6\VWHP 7URXEOH 2XWSXW
The PGM output will activate when any of the selected trouble
conditions are present. It will deactivate when all the selected
trouble conditions are cleared.
The PGM attributes for this option, programmed in sections
[141] to [142], differ from the standard selection of attributes.
Program which trouble conditions will activate the output by
selecting some or all of the following attributes:
Attribute
[1]  6HUYLFH 5HTXLUHG (battery, bell, general trouble,
general tamper, general supervisory)
[2]  $& )DLOXUH
[3]  7HOHSKRQH /LQH 7URXEOH
[4]  )DLOXUH WR &RPPXQLFDWH
[5]  )LUH 7URXEOH  =RQH )DXOW
[6]  =RQH 7DPSHU
[7]  =RQH /RZ %DWWHU\
[8]  /RVV RI &ORFN
>@ 6\VWHP (YHQW 6WUREH 2XWSXW
The output activates when any of the selected system events
(alarms) occur on the system.
127(7KLV RXWSXW ZLOO DFWLYDWH IRU VLOHQW DQG DXGLEOH DODUPV RU
PHGLFDO FRQGLWLRQV RQO\ ,W ZLOO QRW DFWLYDWH GXULQJ SUHDOHUW RU
GHOD\V
If attribute [8] is turned ON, the output will activate for the
number of seconds programmed in the PGM output timer
(section [164]).
If attribute [8] is turned OFF, in the armed state, the output will
deactivate only once the system is disarmed. If an alarm acti-
vates this output in the disarmed state, the output will deacti-
vate if a user enters a valid access code while the Bell Cut-off
timer is counting down. The output will also deactivate if
someone arms the system after the Bell Cut-off has expired.
This output can be used to indicate that an alarm has
occurred before entering the premises.
The PGM attributes for this option, programmed in Sections
[141] to [142], differ from the standard selection of attributes.
Program which events will activate the output by selecting
some or all of the following attributes:
Attribute
[1] %XUJODU\ (Delay, Instant, Interior, Stay/Away and
24 Hour Burglary Zones)
[2] )LUH (Fire Keys, Fire Zones)
[3] 3DQLF (Panic Keys and Panic Zones)
[4] 0HGLFDO (Auxiliary Keys, Medical and Emergency
Zones)
[5] 6XSHUYLVRU\ (Supervisory, Freezer and Water
Zones)

• Entry Delay
• Audible Exit Delay
[6] 3ULRULW\ (Gas, Heat, Sprinkler and 24 Hour Latch-
ing Zones)
[7] +ROGXS (Holdup zones)
[8] 2XWSXW )ROORZV 7LPHU (output will activate for the
number of seconds programmed in the PGM Out-
put Timer)  2XWSXW /DWFKHG
127(,I DWWULEXWH >@ LV WXUQHG 21 DWWULEXWHV >@ PXVW DOVR EH
WXUQHG 21
PGM Output Timer . . . . . . . . . . . . . . . . . . . . . . Section [164]
>@ 6\VWHP 7DPSHU $OO 6RXUFHV
The PGM output will activate when any tamper condition is
present and will deactivate when all tampers are restored.
>@ 7/0 DQG $ODUP
The PGM output activates when the system experiences both
a telephone line trouble and an alarm. When the system is
armed, the output will deactivate only if an access code is
entered or if the telephone line is restored.
If an alarm activates this output in the disarmed state, the out-
put will deactivate if a user enters a valid access code while
the Bell Cut-off timer is counting down, or if the telephone line
is restored. The output will also deactivate if someone arms
the system after the Bell Cut-off has expired.
127(7KLV RXWSXW ZLOO DFWLYDWH IRU DOO VLOHQW DQG DXGLEOH DODUPV
H[FHSW WKH 'XUHVV DODUP DQG KU 3*0 LQSXWV
>@ .LVVRII 2XWSXW
The output will activate for two seconds after the control panel
receives the kissoff transmission from the central station.
>@ *URXQG 6WDUW 3XOVH
The PGM Output will activate for two seconds to obtain a dial
tone on Ground Start telephone equipment before the panel
attempts to dial. Insert two 2-second pauses at the beginning
of the telephone number when using this option.
>@ 5HPRWH 2SHUDWLRQ '/6 6XSSRUW
This output can be activated and deactivated remotely using
the DLS software.
>@ )RU IXWXUH XVH
>@ $ZD\ $UPHG 6WDWXV
When the system is armed in the Away mode, the PGM output
will activate at the beginning of the exit delay. The output
deactivates when the panel is disarmed.
>@ 6WD\ $UPHG 6WDWXV
When the system is armed in the Stay mode, the PGM output
will activate at the beginning of the exit delay. The output
deactivates when the panel is disarmed.
>@ > @>@>@ &RPPDQG 2XWSXW 2SWLRQ 
>@ > @>@>@ &RPPDQG 2XWSXW 2SWLRQ 
These outputs are user-initiated by entering [*][7][1-2] at any
keypad. When any output is activated, three acknowledgment
beeps are sounded.
127(6 RQ 2SWLRQ >@ > @>@>@
Press [*][7][2][Access Code, if required] to activate any out-
put programmed as one of PGM output option [03] or [20].
Traditionally, [*][7][2] has been reserved for resetting smoke
detectors. Smoke detectors should now be programmed as
output [03] "Sensor Reset".
127(2QO\ 21( RI RSWLRQV >@ 6HQVRU 5HVHW DQG >@> @>@>@
&RPPDQG 2XWSXW 2SWLRQ  PD\ EH SURJUDPPHG RQ WKH VDPH
V\VWHP