[014] Second System Option Code
'HIDXOW
2SWLRQ
21
OFF
1
Arm / Disarm Bell Squawk enabled
I________I
OFF
2
Bell Squawk During Auto Arm
I________I
OFF
3
Bell Squawk On Exit Delay
I________I
OFF
4
Bell Squawk On Entry Delay
I________I
OFF
5
Bell Squawk On Trouble
I________I
ON
6
Audible Exit with Urgency
I________I
OFF
7
Exit Delay Termination Enabled
I________I
OFF
8
Fire Bell is Continuous
I________I
[015] Third System Option Code
'HIDXOW
2SWLRQ
21
ON
1
Fire Keys Enabled
I________I
OFF
2
Panic Keys Audible (Bell / Beeps)
I________I
OFF
3
Quick Exit Enabled
I________I
ON*
4
Quick Arming Enabled
I________I
OFF
5
Code Required For Bypassing
I________I
OFF
6
Master Code Not Changeable
I________I
ON
7
TLM Enabled
I________I
OFF
8
TLM Audible (Bell) When Armed
I________I
* When using a PC5132 version 2.1 or older with a Wireless Key, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
'HIDXOW
2SWLRQ
21
ON
1
AC Trouble Displayed
I________I
OFF
2
Trouble Light Flashes if AC Fails
I________I
OFF
3
Blank Keypad When Not Used
I________I
OFF
4
Code Required to Remove Kypd Blanking No Code Required
I________I
ON
5
Keypad Backlighting is enabled
I________I
OFF
6
Power Save Mode enabled
I________I
OFF
7
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
I________I
OFF
8
Keypad Tampers enabled
I________I
[017] Fifth System Option Code
'HIDXOW
2SWLRQ
21
ON
1
Unident. Wireless Key Disarm Enabled Disabled
I________I
OFF
2-8
For future use
I________I
[018] Sixth System Option Code
'HIDXOW
2SWLRQ
21
OFF
1
Troubles are Latching
I________I
OFF
2
Engineer's Reset Enabled
I________I
OFF
3
Automatic Battery Check Enabled
I________I
OFF
4
Contact I.D. Partial Close Identifier is 5 Partial Close Identifier is 4
I________I
OFF
5-8
For future use
I________I
P r o g r a m m i n g
2II
Arm / Disarm Bell Squawk disabled
No Bell Squawk During Auto Arm
No Bell Squawk On Exit Delay
No Bell Squawk On Entry Delay
No Bell Squawk On Trouble
Silent Exit Delay
Exit Delay Termination Disabled
Fire Bell Follows Bell Cut-off
2II
Fire Keys Disabled
Panic Keys Silent
Quick Exit Disabled
Quick Arming Dis. / Function keys Req. Code
No Code Required
Master Code Changeable
TLM Disabled
TLM Trouble Beeps When Armed
2II
AC Trouble Not Displayed
Trouble Light Does Not Follow AC Status
Keypad Active Always
Keypad Backlighting is disabled
Power Save Mode disabled
Keypad Tampers disabled
2II
2II
Troubles Follow Restore
Engineer's Reset Disabled
Normal Battery Tests Only
W o r k s h e e t s
6HFWLRQ 3DJH
5.17
22
5.18
23
5.18
23
5.18
23
3.4
7
5.18
23
5.18
23
5.13
21
6HFWLRQ 3DJH
5.16
22
5.16
22
3.4
7
3.4
7
3.4
7
5.1
13
5.12
21
5.12
21
6HFWLRQ 3DJH
3.4
7
3.4
7
5.22
23
5.22
23
5.23
24
5.22
23
5.17
22
5.25
24
6HFWLRQ 3DJH
5.17
22
6HFWLRQ 3DJH
3.4
7
5.27
24
2.2
3
5.9
17


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents